Effect of Compression, Digital Noise Reduction and Directionality on Envelope Difference Index, Log-Likelihood Ratio

Chinnaraj Geetha1, Puttabasappa Manjula1

  • 1Department of Audiology, All India Institute of Speech and Hearing , Mysore, India.

Audiology Research
|November 12, 2015
PubMed

Related Concept Videos

Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
9.1K
Applications of Logarithms01:28

Applications of Logarithms

Logarithmic functions are powerful tools for simplifying the mathematical representation of phenomena involving exponential changes. Their ability to convert multiplicative relationships into additive ones is especially valuable in various scientific and engineering contexts. One notable application of logarithms is measuring sound intensity, specifically through the decibel (dB) scale used in acoustics.Sound intensity levels vary over an extensive range, from the faintest audible whisper to...
424
Pulse amplitude and quality01:17

Pulse amplitude and quality

Pulse amplitude is a crucial indicator of cardiac health because it provides valuable insights into the strength of left ventricular contractions and the overall uniformity of blood circulation within the vasculature. The strength of the pulse is directly related to the force with which the heart contracts and the volume of blood being pumped.
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
3.7K
Downsampling01:20

Downsampling

When considering a sampled sequence with zero values between sampling instants, one can replace it by taking every N-th value of the sequence. At these integer multiples of N, the original and sampled sequences coincide. This process, known as decimation, involves extracting every N-th sample from a sequence, thereby creating a more efficient sequence.
The Fourier transform of the decimated sequence reveals a combination of scaled and shifted versions of the original spectrum. This...
795
Upsampling01:22

Upsampling

Managing signal sampling rates is essential in digital signal processing to maintain signal integrity. A decimated signal, characterized by a reduced frequency range due to its lower sampling rate, can be upsampled by inserting zeros between each sample. This upsampling process expands the original spectrum and introduces repeated spectral replicas at intervals dictated by the new Nyquist frequency. To refine this zero-inserted sequence, it is passed through a lowpass filter with a cutoff...
703
Characteristics of Practical Op Amps01:16

Characteristics of Practical Op Amps

A difference amplifier, a crucial component in numerous electronic devices, ideally amplifies only the difference-mode signal, which is the difference between two input signals. However, in practical circuits, the output voltage depends on both the differential gain and the common-mode gain.
The ratio of differential gain to the common-mode gain is defined as the common-mode rejection ratio (CMRR). This ratio quantifies the ability of operational amplifiers (op-amps) to reject common-mode...
951