Sandesh Phaphe1, Chanamallappa Ganiger1, Yusuf Ahammed2
1Associate Professor, Department of Orthodontics, School of Dental Sciences, KIMSDU , Karad, Satara, Maharashtra, India .
Background:
Bonding is a very important step in the orthodontic treatment planning. Effective bonding enhances the treatment by reducing the bond failure and thereby reducing the treatment duration and also increases efficiency in orthodontic mechanics. The success of the bonded brackets is negatively affected by contamination with oral fluids such as blood and saliva.
Aim:
The aim of the present study was to evaluate the effect of hardness of water used in removing the etchant on the bracket bond strength.
Materials And Methods:
Seventy five extracted premolars were divided in three groups of 25 each. The teeth in all the three groups were etched with 35% phosphoric acid. The etchant in each of the group I, II and III was removed using distilled water (soft), corporation water (moderately hard) and hard water respectively. Stainless steel brackets were attached using light cure bonding agent (transbond XT, 3M UNITEK) and cured for 10sec with a light cure unit. The shear bond strength was evaluated by mechanical testing machine. Statistically significant differences were defined for p < 0.05.
Result:
The results showed significant increase in bond strength in samples where in soft water was used for cleaning the etchant on the bonding surface.
Conclusion:
Hardness of water used for washing the etchant affects the bracket bond strength. Shear bond strength of soft water is significantly increased compared to moderately hard and very hard water.
More Related Videos
Related Concept Videos
Testing Water Quality
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Quality of Water
Titration in Nonaqueous Solvents
Effect of Sea Water on Concrete
Concrete in areas between tide marks,...
Preparation of Samples for Electron Microscopy