Related Experiment Video
Updated: Mar 30, 2026

Employing the Forced Oscillation Technique for the Assessment of Respiratory Mechanics in Adults
Published on: February 9, 2022
Temporal changes in filtering-facepiece respirator fit
Ziqing Zhuang1, Michael Bergman1, Elizabeth Brochu1
1a National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory , Pittsburgh , Pennsylvania.
Annual fit testing for N95 filtering-facepiece respirators (FFRs) is crucial. Significant weight loss, over 20 lb, necessitates re-testing to ensure proper respirator fit and seal.
Area of Science:
- Occupational Health and Safety
- Respiratory Protection
- Industrial Hygiene
Background:
- N95 filtering-facepiece respirators (FFRs) are critical personal protective equipment.
- Maintaining a proper seal is essential for effective respiratory protection.
- Changes in facial characteristics, such as weight fluctuations, can impact respirator fit.
Purpose of the Study:
- To evaluate changes in N95 FFR fit over time.
- To determine the relationship between weight changes and respirator fit.
- To assess the adequacy of current respirator fit-testing schedules.
Main Methods:
- A three-year longitudinal study involving 229 subjects.
- Six-month intervals for fit testing of N95 FFRs.
- Measurement of inward leakage and filter penetration to assess face seal leakage (FSL).
Main Results:
- Unacceptable N95 FFR fit increased from 10% at Year 1 to 25% by Year 3.
- Subjects experiencing a weight loss of 20 lb or more had a 24% rate of unacceptable fit.
- Respirator fit degradation was linked to time intervals between tests and significant weight loss.
Conclusions:
- Current annual fit testing requirements are supported by the study findings.
- Significant weight loss (≥ 20 lb) is a key indicator for mandatory respirator re-testing.
- Regular fit assessment is vital for ensuring the continued effectiveness of N95 FFRs in occupational settings.