Related Experiment Video
Updated: Mar 29, 2026

07:17
Non-equilibrium Microwave Plasma for Efficient High Temperature Chemistry
Published on: August 1, 2017
13.3K
A reliable, compact, and repetitive-rate high power microwave generation system
Wei Li1, Zhi-qiang Li1, Xiao-liang Sun1
1College of Optoelectronics Science and Engineering, National University of Defense Technology, Changsha, Hunan 410073, China.
The Review of Scientific Instruments
|December 3, 2015
Summary
A compact high power microwave (HPM) generation system achieves 1 GW output power. This HPM system utilizes a Marx generator and diffraction output magnetron for efficient microwave generation.
Area of Science:
- Engineering
- Physics
- Electromagnetics
Background:
- High power microwave (HPM) generation systems are crucial for various applications.
- Compact and efficient HPM systems are in demand for deployment flexibility.
Purpose of the Study:
- To describe a compact high power microwave (HPM) generation system.
- To detail the performance characteristics of the developed HPM system.
Main Methods:
- The HPM system comprises a Marx generator with a pulse forming line and a diffraction output magnetron.
- The system's physical dimensions are 120 cm in length and 250 kg in weight.
Main Results:
- The system generates 1 GW of microwave power at 2.32 GHz.
- Achieved 23% power conversion efficiency with a 38 ns pulse duration.
- Demonstrated low time and amplitude jitters (<4 ns and <1.5 dB, respectively) in burst mode.
Conclusions:
- The developed compact HPM system offers significant power output and efficiency.
- The system's compact design and stable performance make it suitable for diverse applications.
- Further research can explore scaling and integration possibilities for advanced HPM technologies.
Related Concept Videos
Standing Waves in a Cavity
1.6K
A household microwave and lasers are examples of standing electromagnetic waves in a cavity. When two conducting metal plates are placed parallel at the nodal planes, it creates a cavity where standing waves are formed. The cavity between the two planes is analogous to a stretched string held at the points x = 0 and x = L. Here, the distance 'L' between the two planes must be an integer multiple of half of the wavelength. The wavelengths that satisfy this condition are given by:
1.6K
Generating Electromagnetic Radiations
8.4K
The German physicist Heinrich Hertz (1857–1894) was the first to generate and detect certain types of electromagnetic waves in the laboratory. Starting in 1887, he performed a series of experiments that confirmed the existence of electromagnetic waves and verified that they travel at the speed of light. Hertz used an alternating-current RLC (resistor-inductor-capacitor) circuit that resonated at a known frequency and connected it to a loop of wire. High voltages induced across the gap in...
8.4K
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
2.0K
A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
2.0K
Maximum Power Transfer
1.1K
Numerous practical applications within engineering disciplines, such as telecommunications, necessitate optimizing power delivery to a connected load. This pursuit, however, entails inherent internal losses, which can either equal or exceed the power supplied to the load. The Thevenin equivalent circuit is helpful in finding the maximum power a linear circuit can deliver to a load. It is assumed in this context that the load resistance can be adjusted.
By substituting the entire circuit with...
By substituting the entire circuit with...
1.1K