Optimized efficiency of mapping a site contaminated with dioxins by immunoassay compared to gas chromatography-high
Ching Lo1,2,3, Eric Buan4, James Li4,5
1Environmental Applied Science and Management, Ryerson University, 350 Victoria Street, Toronto, Ontario, M5B 2K3, Canada. ching.lo@gmail.com.
Abstract:
The use of an enzyme-linked immunosorbent assay (ELISA) to screen for polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/F) has shown promise as a complementary tool to gas chromatography-high resolution mass spectrometry (GC-HRMS). This is especially true due to its low cost, ease of sample preparation and fast sample turnaround time. One problem that was unaddressed by other research is how to increase the efficiency of ELISA to a point that makes it practical for the analysis of large groups of samples that can have a wide range of unknown PCDD/F concentrations; one ELISA test is unable to screen for PCDD/F concentrations that can range anywhere from background levels to upwards of 10,000 picograms toxic equivalents per gram of soil (pgTEQ g(-1)). This paper resolves this problem by introducing a sample algorithm which enables the correct amount of dioxin to enter an ELISA tube from a sample (whose unknown PCDD/F concentration can range between 30 and 10,500 pgTEQ g(-1)) in only two ELISA runs. In doing so, the time and cost benefits of ELISA are preserved. ELISA results for soils and sediment samples processed using the algorithm were then plotted on two site maps alongside their GC-HRMS counterparts. A comparison of both analytical methods showed that areas of high and low PCDD/F concentrations were equally identifiable with either analytical tool; 29 of 32 sample locations on the site maps were placed into the same of three possible screening levels. Therefore, processing ELISA samples through the sample algorithm achieves the necessary level of efficiency while producing virtually equal screening results in comparison to GC-HRMS but at a fraction of the cost. The agreement between GC-HRMS and ELISA was 94% (R (2) = 0.99, n = 53). GC-HRMS and ELISA results were significantly correlated (Wilcoxon signed rank test p < 0.001).
More Related Videos
12:03Two-Dimensional Visualization and Quantification of Labile, Inorganic Plant Nutrients and Contaminants in Soil
Published on: September 1, 2020
09:34Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
Published on: September 20, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...