Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Data Validation01:15

Data Validation

3.6K
Method validation is a crucial process in analytical chemistry designed to confirm that a given method consistently produces reliable and high-quality results. This process is essential when a method is applied to different sample matrices or when procedural modifications are made, ensuring that the results meet acceptable standards across various applications.
Key parameters for method validation include:
3.6K
High-Performance Liquid Chromatography: Instrumentation00:57

High-Performance Liquid Chromatography: Instrumentation

3.5K
High-performance liquid chromatography, or HPLC, is an analytical technique that separates liquid samples under high pressures. An HPLC instrument consists of glass bottles for storing solvents called mobile phase reservoirs. HPLC-grade solvents are used to maintain high purity, and the dissolved gases are removed using a degasser, such as a vacuum pumping system or sparging with helium. The solvents are then pumped into the analytical column using a screw-driven syringe or reciprocating pumps.
3.5K
High-Performance Liquid Chromatography: Elution Process01:05

High-Performance Liquid Chromatography: Elution Process

2.0K
In High-Performance Liquid Chromatography (HPLC), the elution process is critical to the separation of analytes and the quality of chromatographic results. Elution describes how compounds move through the column and separate based on their interactions with the mobile and stationary phases. This process determines the resolution, peak shape, and retention times in the chromatogram, which are essential for identifying and quantifying components in complex mixtures. Understanding the elution...
2.0K
High-Performance Liquid Chromatography: Introduction01:11

High-Performance Liquid Chromatography: Introduction

4.1K
High-performance liquid chromatography(HPLC), formerly referred to as High-pressure liquid chromatography, is a powerful technique used to separate, identify, and quantify components in complex mixtures. The term "high pressure" refers to using high pressure to push the liquid mobile phase through the tightly packed columns.
In HPLC, two phases play a critical role in the separation process:
4.1K
Chromatographic Methods: Classification01:12

Chromatographic Methods: Classification

4.6K
Chromatographic techniques are classified in three ways: the classification is based on the physical state of the stationary and mobile phases, how the mobile phase and the stationary phase contact each other, or through the chemical or physical processes that isolate the components of the sample. Typically, the mobile phase is either a liquid or gas, while the stationary phase is either a solid or a liquid layer applied to a solid surface.
Chromatographic techniques are typically named by...
4.6K
Optimizing Chromatographic Separations01:15

Optimizing Chromatographic Separations

1.2K
Optimizing chromatographic separations is crucial for obtaining clean separations in a minimum amount of time. Optimization is required for several factors, including kinetic effects related to band broadening, plate height, capacity factor, and separation factor.
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
1.2K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Navigating the AQbD Landscape: Enhancing Quality Management in Liquid Chromatography Method Development.

Biomedical chromatography : BMC·2025
Same author

Polysaccharide and Cyclodextrin-Based Monolithic Chiral Stationary Phases and its Application to Chiral Separation.

Combinatorial chemistry & high throughput screening·2023
Same author

Chiral Inversion of Pharmaceutical Drugs - Mini Review.

Combinatorial chemistry & high throughput screening·2023
Same author

Impact of cyclofructan derivatives as efficient chiral selector in chiral analysis: An overview.

Chirality·2021
Same author

D-Optimal mixture design optimization of an HPLC method for simultaneous determination of commonly used antihistaminic parent molecules and their active metabolites in human serum and urine.

Biomedical chromatography : BMC·2017
Same author

Stability-Indicating HPLC Method for the Simultaneous Determination of HIV Tablet Containing Emtricitabine, Tenofovir Disoproxil Fumarate, and Rilpivirine Hydrochloride in Pharmaceutical Dosage Forms.

International scholarly research notices·2016

Related Experiment Video

Updated: Mar 29, 2026

Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
11:00

Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS

Published on: May 20, 2013

23.6K

Systematic Robustness Testing of a Liquid Chromatographic Method: A Case Study.

Sai Sandeep Mannemala1, Valliappan Kannappan

  • 1Annamalai University, Faculty of Engineering and Technology, Department of Pharmacy, Annamalai Nagar, Tamil Nadu 608002, India.

Journal of AOAC International
|December 15, 2015
PubMed
Summary

Robustness testing ensures method reliability. This study used experimental design to identify critical factors affecting warfarin and impurity analysis, finding aqueous content significantly impacts separation.

More Related Videos

Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
07:34

Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS

Published on: March 14, 2013

13.6K
Multi-step Preparation Technique to Recover Multiple Metabolite Compound Classes for In-depth and Informative Metabolomic Analysis
11:25

Multi-step Preparation Technique to Recover Multiple Metabolite Compound Classes for In-depth and Informative Metabolomic Analysis

Published on: July 11, 2014

35.2K

Related Experiment Videos

Last Updated: Mar 29, 2026

Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
11:00

Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS

Published on: May 20, 2013

23.6K
Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
07:34

Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS

Published on: March 14, 2013

13.6K
Multi-step Preparation Technique to Recover Multiple Metabolite Compound Classes for In-depth and Informative Metabolomic Analysis
11:25

Multi-step Preparation Technique to Recover Multiple Metabolite Compound Classes for In-depth and Informative Metabolomic Analysis

Published on: July 11, 2014

35.2K

Area of Science:

  • Analytical Chemistry
  • Chromatography

Background:

  • Method reliability is crucial for analytical procedures.
  • Robustness testing identifies variability sources in method responses.
  • Simultaneous determination of warfarin and impurities requires a validated method.

Purpose of the Study:

  • To evaluate the robustness of a method for simultaneous determination of warfarin and its impurities.
  • To identify critical method parameters affecting chromatographic separation.
  • To establish acceptable operational ranges for method transfer.

Main Methods:

  • Two-level fractional factorial design was employed for robustness testing.
  • Independent variables included aqueous content, acetic acid concentration, flow rate, and wavelength.
  • Responses measured were retention factor, resolution, tailing factor, and analysis time.

Main Results:

  • Aqueous content was identified as a significant factor affecting capacity factor and analysis time.
  • Graphical (half normal probability, Pareto plots) and statistical (ANOVA) methods assessed robustness.
  • Contour profiling defined non-significant intervals for critical factors.

Conclusions:

  • Experimental design is vital for understanding chromatographic system factors.
  • Statistical tools aid in defining operational limits for method robustness.
  • The study successfully demonstrated a robust method for warfarin and impurity analysis.