Wideband Optical Detector of Ultrasound for Medical Imaging Applications
Published on: May 11, 2014
[Interference Detection and Signal Quality Assessment of Pulse Signals]
Abstract:
Pulse signal contains a wealth of biological and pathological information. However, it is susceptible to the influence of various factors which results in poor signal quality, and causes the device to generate false alarms. First the pulse signals are processing into discrete symbols, and then compare the test signal with the pulse template by using Dynamic Time Warping (DTW) to get the threshold for which can be used to find the interference segment of the test signal. By analyzing the DTW distance of the pulse signal, we can get the interference degree of the signal, then the quality level of the plus signal can be defined by the relationship between the interference degree and quality of the signal. The 1 055 group pulse signals provided by MIMIC II physiological database are used to train and test the signal quality assessment algorithms, and compared with other existing algorithms. The results show that the algorithms can accurately detect interference segments in pulse signal and reflect the quality of it.
More Related Videos
05:11High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition
Published on: June 27, 2025
06:55Developing a Behavioral Box for Assessing Prepulse Inhibition and Neural Activity in Psychiatric Animal Models
Published on: July 22, 2025
Related Concept Videos
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Special considerations while measuring pulse
Interference: Path Lengths
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: