Related Experiment Video
Updated: Mar 28, 2026

A Postoperative Evaluation Guideline for Computer-Assisted Reconstruction of the Mandible
Published on: January 28, 2020
Retrospective study of mandibular angle fractures treated with three different fixation systems
Krushna Bhatt1, Satyavrat Arya1, Ongkila Bhutia1
1Department of Oral and Maxillofacial Surgery, Center for Dental Education and Research, All India Institute of Medical Sciences, New Delhi, India.
Aim:
To evaluate the outcomes of mandibular angle fractures treated with metal 2.0 mm locking, metal 2.0 mm nonlocking, and 2.5 mm resorbable systems.
Study Design:
Retrospective cohort study.
Materials And Methods:
Trauma records were screened for linear angle fractures treated with open-reduction and internal semi-rigid fixation with single metal/bioresorbable plates, and baseline variables were tabulated. The outcome variable was the presence or absence of any complication.
Statistical Analysis Used:
The Fisher's exact test and analysis of covariance (ANCOVA) using STATA 11.
Results:
A total of 60 case records of over four years were included. The mean age of the patients was 27.4 (SD 9.7) years. Fifty-five were male and five female. There were 20 nonlocking and 16 locking metal miniplates and 24 bioresorbable plates. In 55 (91.6%) cases there was a third molar in the fracture line. In 51/55 (92.7%) cases the third molar was retained. In seven patients postoperative complications were seen. There was no difference between the complication rates of the three treatment groups. Infection was the most common complication followed by delayed union and hardware failure.
Conclusions:
This retrospective study found no difference in the complication rate when fractures of the mandibular angle were treated with locking or nonlocking miniplates or bioresorbable plates.