An integrated biomechanical modeling approach to the ergonomic evaluation of drywall installation

Lu Yuan1, Bryan Buchholz2, Laura Punnett2

  • 1Department of Computer Science and Industrial Technology, Southeastern Louisiana University, SLU 10847, Hammond, LA, 70402, USA; Department of Work Environment, University of Massachusetts Lowell, 1 University Avenue, Lowell, MA, 01854, USA.

Applied Ergonomics
|December 18, 2015
PubMed

Related Concept Videos

Method of Joints: Problem Solving II01:30

Method of Joints: Problem Solving II

Consider a truss structure with frictionless joints fixed to a wall and roller support. If a force of 150 N is applied to joint A, the forces in each member of the truss can be determined using the method of joints.
1.2K
Internal Loadings in Structural Members: Problem Solving01:28

Internal Loadings in Structural Members: Problem Solving

When designing or analyzing a structural member, it is important to consider the internal loadings developed within the member. These internal loadings include normal force, shear force, and bending moment. Engineers can ensure that the structural member can support the applied external forces by calculating these internal loadings.
To illustrate this, let's consider a beam OC of 5 kN, inclined at an angle of 53.13° with the horizontal and supported at both ends. Determine the internal...
1.8K
Design Example: Dimensioning of Concrete Masonry Construction01:13

Design Example: Dimensioning of Concrete Masonry Construction

For the construction of a storeroom using concrete masonry units, it's essential to align the dimensions of the structure with the actual sizes of the blocks and the intended mortar joints. On the site in question, there's a stockpile of concrete masonry blocks with a nominal size of eight by eight by sixteen inches, which are to be used in the construction of the storeroom.
The site engineer has laid out a plan for the storeroom with external dimensions of twelve feet in length and...
380
Frames: Problem Solving II01:26

Frames: Problem Solving II

Consider a hydraulic hoist supporting a load of 1 kN. Assuming a simplified schematic representation of this frame structure, the force acting on BD and BF members can be determined.
544
Method of Sections: Problem Solving II01:30

Method of Sections: Problem Solving II

Consider an arbitrary truss structure composed of diagonal, vertical, and horizontal members fixed to the wall. To calculate the force acting on members CB, GB, and GH, method of sections can be used. The loads and lengths of the horizontal and vertical members are known parameters, as shown in the figure.
1.8K
Machines: Problem Solving I01:22

Machines: Problem Solving I

A toggle clamp is a mechanical device commonly used for holding and clamping objects in various applications, such as woodworking, metalworking, and assembly operations. Consider a toggle clamp subjected to a force of 200 N at the handle. The vertical clamping force can be calculated, provided the dimensions of the toggle clamp are known.
The toggle clamp system is a machine structure consisting of movable, pin-connected multi-force members that form a stabilized system to transmit forces. The...
797