Related Experiment Video
Updated: Mar 28, 2026

A Postoperative Evaluation Guideline for Computer-Assisted Reconstruction of the Mandible
Published on: January 28, 2020
Cone beam computed tomography-based models versus multislice spiral computed tomography-based models for assessing
Liliane Rosas Gomes1, Marcelo Regis Gomes2, João Roberto Gonçalves3
1Department of Orthodontics, Faculdade de Odontologia de Araraquara, UNESP Universidade Estadual Paulista, Sao Paulo, Brazil; Department of Orthodontics, School of Dentistry, University of Michigan, Ann Arbor, MI, USA.
Objective:
To quantitatively compare condylar morphology using cone beam computed tomography (CBCT) and multislice spiral computed tomography (MSCT) virtual three-dimensional surface models.
Study Design:
The sample consisted of secondary data analyses of CBCT and MSCT scans obtained for clinical purposes from 74 patients treated with condylar resection and prosthetic joint replacement. Three-dimensional surface models of 146 condyles were constructed from each scan modality. Across-subject models were approximated and voxel-based registration was performed between homologous CBCT and MSCT images, making it possible to create average CBCT- and MSCT-based condylar models. SPHARM-PDM software provided matching points on each corresponding model. ShapeAnalysisMANCOVA software assessed statistically significant differences between observers and imaging modalities. One-sample t-tests evaluated the null hypothesis that the mean differences between each CBCT- and MSCT-based model were not clinically significant (<.5 mm). Tests were conducted at a significance level of P < .05.
Results:
ShapeAnalysisMANCOVA showed no statistically significant difference between the average CBCT- and MSCT-based models (P > .68). During pairwise comparison, the mean difference observed was .406 mm (SD, .173). One sample t-test showed that mean differences between each set of paired CBCT- and MSCT-based models were not clinically significant (P = .411).
Conclusion:
Three-dimensional surface models constructed from CBCT images are comparable to those derived from MSCT scans and may be considered reliable tools for assessing condylar morphology.
More Related Videos
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...

