Dead or alive? New confirmatory test using quantitative analysis of computed tomographic angiography
Lorena P Suarez-Kelly1, Dhruv A Patel, Peter M Britt
1From the Departments of Surgery (L.P.S.-K., W.J.B., F.E.D.), and Radiology (D.A.P., P.M.B.), and The Curtis and Elizabeth Anderson Cancer Institute (E.J.C.), Memorial University Medical Center; Department of Surgery (W.J.B., F.E.D.), Mercer University School of Medicine; and Neurologic Institute of Savannah & Center for Spine (J.U.H.), Savannah; and Department of Surgery (C.M.M.), Liberty Regional Medical Center, Hinesville, Georgia.
Computed tomographic angiography (CTA) can confirm brain death (BD) when nuclear medicine perfusion tests (NMPT) are unreliable. A CTA Hounsfield unit threshold of less than 80 in key cerebral arteries indicates absent physiologic cerebral perfusion, confirming BD with high accuracy.
Area of Science:
- Neurology
- Radiology
- Medical Diagnostics
Background:
- Clinical examination can be unreliable for diagnosing brain death (BD).
- Nuclear medicine perfusion test (NMPT) is the preferred confirmatory test for BD at our institution.
- Computed tomographic angiography (CTA) has emerged as a potential alternative for BD confirmation.
Purpose of the Study:
- To quantitatively analyze CTA for BD diagnosis.
- To assess the accuracy of CTA compared to NMPT.
- To define specific parameters for BD confirmation using CTA.
Main Methods:
- Prospective clinical study (2007-2014) of 60 clinically brain dead patients and 20 controls.
- NMPT performed as the reference standard, immediately followed by CTA.
- Quantitative assessment of CTA Hounsfield units in the middle cerebral artery (M1), anterior cerebral artery (A1), and basilar artery (BA).
Main Results:
- 88% of patients showed absent cerebral blood flow (CBF) on NMPT.
- Only 50% showed absent CBF on CTA.
- Established criteria using CTA Hounsfield units to differentiate preserved perfusion from stasis filling, with significant variations across all measured arteries (p < 0.001).
Conclusions:
- A CTA Hounsfield unit value less than 80 in M1, A1, and BA correlates with absent CBF on NMPT.
- This threshold indicates a lack of physiologic cerebral perfusion, confirming brain death.
- CTA demonstrates high diagnostic accuracy for BD confirmation, with 97% sensitivity and 100% specificity.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies III: Computed Tomography
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...