Development a polymer-based electronic pulse diagnosis instrument for measuring and analyzing pulse wave velocity
Summary
This study introduces a flexible pulse diagnosis system using conductive elastic polymer for accurate pulse wave velocity measurement, crucial for cardiovascular disease assessment.
Area of Science:
- Biomedical Engineering
- Medical Devices
- Cardiovascular Diagnostics
Background:
- Pulse wave velocity (PWV) is a key indicator for cardiovascular health.
- Conventional pulse diagnosis instruments are often rigid and lack flexibility.
- There is a need for advanced, flexible systems for precise PWV measurement.
Purpose of the Study:
- To propose and evaluate a novel, flexible pulse-diagnosis system for measuring pulse wave velocities.
- To demonstrate the system's feasibility in applications related to cardiovascular diseases.
- To assess the performance of the developed system through sample measurements.
Main Methods:
- Utilized a conductive elastic polymer as the sensor material for flexibility.
- Integrated a flexible sensor with a wrist-type pulse-wave acquisition system.
- Employed the LabVIEW platform for signal processing and pulse waveform reconstruction from cun, guan, and chi signals.
Main Results:
- Successfully fabricated a flexible pulse diagnosis instrument with enhanced formability.
- Demonstrated stable measurements through integration with a contemporary wrist-type system.
- Analyzed 20 measured samples to evaluate system performance and feasibility.
Conclusions:
- The novel flexible pulse diagnosis system shows promise for accurate PWV measurement.
- The system's design facilitates stable and reliable data acquisition.
- This technology offers a feasible approach for cardiovascular disease risk assessment.
Related Concept Videos
Special considerations while measuring pulse
1.1K
Assessing a patient's pulse is a fundamental skill in healthcare, but certain situations require special attention:
1.1K
Pulse
2.6K
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
The pulse serves as a clinical...
2.6K
Voltammetric Techniques: Pulse Voltammetry
1.8K
Differential-pulse voltammetry (DPV) is a type of voltammetry that involves applying a series of voltage pulses to an electrochemical cell while measuring the resulting current. In DPV, the differential pulse or small potential pulses are superimposed on a linear potential sweep. The magnitude of these pulses is typically small, often in the millivolt range. Each voltage pulse lasts a short duration, usually in the order of a few milliseconds, and is applied at regular intervals along the...
1.8K
Pulse rhythm
1.6K
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
1.6K
Equipments Used To Measure Blood Pressure
3.9K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
3.9K
Electronic Distance Measuring Instruments
669
Electronic Distance Measuring Instruments (EDMs) are essential tools in modern surveying, offering precise distance measurements by emitting electromagnetic signals and calculating the time required for these signals to travel to a target and return. Two primary types of signals are used in EDMs — light waves and microwaves — each suited to specific environmental and distance requirements. Light-wave-based EDMs utilize either infrared or laser light, providing high accuracy over...
669