Individually tailored contrast enhancement in CT pulmonary angiography
Babs M F Hendriks1,2, Madeleine Kok1,2, Casper Mihl1,2
11 Departments of Radiology, Maastricht University Medical Center, Maastricht, Netherlands.
Objective:
The purpose was to evaluate individually shaped contrast media (CM) delivery in CT pulmonary angiography (CTPA) for suspected pulmonary embolism (PE).
Methods:
100 consecutive emergency patients with clinical suspicion of PE were evaluated. High-pitch CTPA was performed on a second-generation dual-source CT using the following parameters: 100 kV, 200-250 mAsref, rotation time 0.28 s, 128 × 0.6 mm col. and image reconstruction 1.0/0.8 mm (B30f). Group 1 (n = 50) then received a fixed CM bolus (300 = mgI ml(-1), volume = 90 ml and flow rate = 6 ml s(-1)); Group 2 (n = 50) received a body weight-adapted CM bolus determined by dedicated contrast injection software. For analysis, groups were further subdivided into low-weight (40-75 kg) and high-weight (76-117 kg) groups. Technical image quality was graded using a four-point Likert scale (1 = non-diagnostic; 2 = diagnostic; 3 = good and 4 = excellent image quality) at the level of the pulmonary trunk and pulmonary arteries. Objective image quality analysis was performed by measuring contrast enhancement in Hounsfield units (HU) at the same levels. Attenuation levels > 180 HU were considered diagnostic.
Results:
All examinations were graded as diagnostic at each level. The individual minimum pulmonary attenuation was 184 and 270 HU for Group 1 and 2, respectively. Mean attenuation was as follows: Group 1: 475 ± 105 HU (40-75 kg) and 402 ± 115 HU (76-117 kg), p < 0.03. Group 2: 424 ± 76 HU (40-75 kg) and 418 ± 100 HU (76-117 kg), p = 0.8. For Group 2, CM volumes were: 55 ± 5 ml (40-75 kg) and 66 ± 5 ml (76-117 kg), leading to 16-51% CM reduction.
Conclusion:
Even under emergency conditions, individualized CM protocols can provide diagnostic and robust image quality in CTPA for PE with a substantial reduction of CM volume for lower weight patients, compared with a fixed CM protocol.
Advances In Knowledge:
CM volume can substantially be reduced by using individualized CM protocols in CT angiography for PE without compromising the diagnostic image quality.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
12:15Tissue Preparation Techniques for Contrast-Enhanced Micro Computed Tomography Imaging of Large Mammalian Cardiac Models with Chronic Disease
Published on: February 8, 2022
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Radiological Investigation I: X-ray and CT