Assessment of wear facets produced by the ACTA wear machine
Ana R Benetti1, Liselotte Larsen1, Adam H Dowling2
1Section for Oral Rehabilitation, Dental Materials and Oral Diagnostics, Department of Odontology, Faculty of Health and Medical Sciences, University of Copenhagen, Denmark.
Objective:
To investigate the use of a three-dimensional (3D) digital scanning method in determining the accuracy of the wear performance parameters of resin-based composites (RBCs) determined using a two-dimensional (2D) analogue methodology following in-vitro testing in an Academisch Centrum for Tandheelkunde Amsterdam (ACTA) wear machine.
Methods:
Specimens compatible with the compartments of the ACTA wear machine specimen wheel (n=10) were prepared from one commercial and four experimental RBCs. The RBC specimens were rotated against an antagonist wheel in a food-like slurry for 220,000 wear cycles. The mean wear depth was measured using the traditionally employed 2D and compared with the 3D profilometric (digital) techniques. Data were submitted to analyses of variance, Tukey's post hoc tests and Independent Samples Student's t-tests (where appropriate) at p<0.05.
Results:
The RBC rank achieved for mean wear depth calculations were similar whether the 2D or 3D techniques were employed. However, the mean wear depth values obtained from the 3D digital technique were significantly increased for two of the five RBC materials compared with the 2D methodology. The total volumetric wear data provided an assessment of the potential of the experimental RBC formulations for clinical usage.
Conclusion:
The 3D technique allowed for the assessment of mean maximum wear depth and mean total volumetric wear which enables tribological analyses of the wear facet and therefore the wear mechanisms operative. Employing the 2D profile technique ranks RBC materials in terms of in-vitro wear performance.
Clinical Significance:
Confidence in the wear volume measurements can only be achieved if the wear facet is analysed with sufficient resolution using a 3D digital measurement technique. However, the employment of 2D profilers is useful when screening potential new RBC formulations for the restoration of posterior dentition.
More Related Videos
07:47Experimental Protocol to Investigate Particle Aerosolization of a Product Under Abrasion and Under Environmental Weathering
Published on: September 16, 2016
08:47Mimicking and Measuring Occlusal Erosive Tooth Wear with the "Rub&Roll" and Non-contact Profilometry
Published on: February 2, 2018
Related Concept Videos
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Toughness and Hardness of Aggregate
Fatigue
Wedges
Consider using a wedge to lift a heavy slab. Here, the wedge functions by converting the applied force into a much larger force directed almost perpendicular to the initial force. This...
Mechanical Characteristics of Steel
The tension test is fundamental for determining tensile strength. In this test, a steel specimen is stretched using a gripping device until it breaks. The data collected during this test are used...
Characteristics of Dry Friction
Before the wheelbarrow starts moving, the static frictional force acts tangentially to the contact surface, opposing the force that is about to induce the motion. This frictional force prevents the...