Related Experiment Video
Updated: Mar 28, 2026

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Use of an anatomic long-stemmed component in femoral impaction grafting
Richard W Westerman1, Andrew J Timperley1
1Princess Elizabeth Orthopaedic Centre, Royal Devon and Exeter NHS Foundation Trust, Exeter - UK.
Abstract:
We describe a challenging femoral revision for aseptic loosening in a relatively young and active man. The femur had gross osteolysis, an absent calcar and a cortical diaphyseal defect at the level of the isthmus (Paprosky 3b defect). The cortical defects were repaired and the whole femur then restored with Femoral Impaction Grafting (FIG) using custom-made impaction instruments and an anatomic shaped collarless, polished, tapered femoral component.In the active adult, bone restoring revision techniques such as impaction grafting should be considered to give a realistic prospect of host bone augmentation rather than simply aiming for a distally fixed stem in a patulous femoral canal.
More Related Videos
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022
09:09A Modified Heterotopic Swine Hind Limb Transplant Model for Translational Vascularized Composite Allotransplantation VCA Research
Published on: October 14, 2013