Kinetic models for nitrogen inhibition in ANAMMOX and nitrification process on deammonification system at room
Marina C De Prá1, Airton Kunz2, Marcelo Bortoli3
1Department of Chemical Engineering, Federal University of Santa Catarina, UFSC, Florianópolis, SC, Brazil.
Abstract:
In this study were fitted the best kinetic model for nitrogen removal inhibition by ammonium and/or nitrite in three different nitrogen removal systems operated at 25 °C: a nitrifying system (NF) containing only ammonia oxidizing bacteria (AOB), an ANAMMOX system (AMX) containing only ANAMMOX bacteria, and a deammonification system (DMX) containing both AOB and ANAMMOX bacteria. NF system showed inhibition by ammonium and was best described by Andrews model. The AMX system showed a strong inhibition by nitrite and Edwards model presented a best system representation. For DMX system, the increased substrate concentration (until 1060 mg NH3-N/L) tested was not limiting for the ammonia consumption rate and the Monod model was the best model to describe this process. The AOB and ANAMMOX sludges combined in the DMX system displayed a better activity, substrate affinity and excellent substrate tolerance than in nitrifying and ANAMMOX process.
Related Concept Videos
Inorganic Nitrogen Assimilation
Metabolism of Chemolithotrophs
Overview of Nitrogen Metabolism
The largest pool of nitrogen available in the terrestrial ecosystem is gaseous nitrogen (N2) from the air, but this...
2° Amines to N-Nitrosamines: Reaction with NaNO2
1° Amines to Diazonium or Aryldiazonium Salts: Diazotization with NaNO2 Mechanism
The Nitrogen Cycle