Related Experiment Video
Updated: Mar 28, 2026

Fabrication of Mechanically Tunable and Bioactive Metal Scaffolds for Biomedical Applications
Published on: December 8, 2015
Porous Ti6Al4V alloys with enhanced normalized fatigue strength for biomedical applications
Fuping Li1, Jinshan Li1, Hongchao Kou1
1State Key Laboratory of Solidification Processing, Northwestern Polytechnical University, Xi'an 710072, P.R. China.
Abstract:
In this paper, porous Ti6Al4V alloys for biomedical applications were fabricated by diffusion bonding of alloy meshes. The compression-compression fatigue behavior was studied. It results that porous Ti6Al4V alloys show enhanced normalized fatigue strength which is in the range of 0.5-0.55 at 10(6)cycles. The porosity has some effect on the absolute S-N curves but minor effect on the normalized S-N curves. The relationship between strain per cycle and number of cycles shows three distinct stages and the value of strain per cycle is constant in stage II. The reasons for the higher normalized fatigue strength of porous Ti6Al4V alloys are discussed based on the fatigue crack initiation and propagation.