Approaches to ultra-low radiation dose coronary artery calcium scoring based on 3rd generation dual-source CT: A
Andrew D McQuiston1, Giuseppe Muscogiuri2, U Joseph Schoepf3
1Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, USA.
Objectives:
To investigate to what extent 3rd generation dual-source computed tomography (DSCT) can reduce radiation dose in coronary artery calcium scoring.
Methods:
Image acquisition was performed using a stationary calcification phantom. Prospectively electrocardiogram (ECG)-triggered 120 kV sequential, and 120 and Sn100 kV ultra-high pitch (UHP) acquisitions were performed with different tube currents (80, 60, 40, 20 mA). Images were reconstructed using filtered back projection (FBP) and 3rd generation iterative reconstruction (IR). Contrast-to-noise ratio (CNR), Agatston score, calcium volume, and radiation dose were assessed. For statistical analysis Friedman tests and Wilcoxon rank sum tests were used.
Results:
Even at reduced tube currents, the three acquisition techniques did not show significant differences in Agatston score (p=0.4) or calcium volume (p=0.08) with FBP reconstruction. Calcium volumes were significantly lower for 3rd generation IR compared to FBP reconstructions (p<0.01). CTDIvol for the 120 kV sequential, 120 and Sn100 kV UHP acquisitions at 80 and 20 mA were 1.2-0.37, 0.48-0.17, and 0.07-0.02 mGy, respectively.
Conclusion:
3rd generation DSCT enabled a reduction of tube current in both the sequential and UHP acquisitions without significantly affecting coronary calcium scoring. Tin filtered 100 kV scanning may allow accurate quantification of calcium score without correction of the HU threshold.
More Related Videos
06:57Author Spotlight: Advancing Cardiovascular Imaging - Introducing the Spatially Weighted Calcium Score for Early Disease Detection
Published on: September 22, 2023
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System IV: CMRI