Related Experiment Video
Updated: Mar 28, 2026

Novel and Innovative Hybrid Technique for Type A Aortic Dissection
Published on: March 28, 2025
A Case of Disseminated Intravascular Coagulation after Thoracic Endovascular Aortic Repair
1Department of Cardiovascular Surgery, Bell Land General Hospital, Sakai, Osaka, Japan.
Abstract:
I report a hemorrhagic complication due to disseminated intravascular coagulation after thoracic endovascular aortic repair for a dissecting aortic aneurysm. A 74-year-old man underwent thoracic endovascular aortic repair and carotid-carotid artery bypass to close the primary entry site of the dissecting aortic aneurysm. Postoperatively, he developed a gradually expanding cervical hematoma. Laboratory data showed disseminated intravascular coagulation. He could not extubated until postoperative day 6 because of the risk of airway obstruction. He was treated with transfusion to replenish the coagulation factor. Disseminated intravascular coagulation may occur secondary to thrombus formation in the false lumen after thoracic endovascular aortic repair.
Related Concept Videos
Aneurysm III: Interprofessional Care
Venous Thrombosis III: Interprofessional Care
Venous Thrombosis I: Introduction
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care