Related Experiment Video
Updated: Mar 28, 2026

A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
Comparison of partners-heart failure algorithm vs care alert in remote heart failure management
Leonardo Calo'1, Annamaria Martino1, Claudia Tota1
1Leonardo Calo', Annamaria Martino, Claudia Tota, Alessandro Fagagnini, Renzo Iulianella, Marco Rebecchi, Luigi Sciarra, Ermenegildo de Ruvo, Division of Cardiology, Policlinico Casilino, 00169 Rome, Italy.
Aim:
To compare the utility of the partners-heart failure (HF) algorithm with the care alert strategy for remote monitoring, in guiding clinical actions oriented to treat impending HF.
Methods:
Consecutive cardiac resynchronization-defibrillator recipients were followed with biweekly automatic transmissions. After every transmission, patients received a phone contact in order to check their health status, eventually followed by clinical actions, classified as "no-action", "non-active" and "active". Active clinical actions were oriented to treat impending HF. The sensitivity, specificity, positive and negative predictive values and diagnostic accuracy of the partners-HF algorithm vs care alert in determining active clinical actions oriented to treat pre-HF status and to prevent an acute decompensation, were also calculated.
Results:
The study population included 70 patients with moderate to advanced systolic HF and QRS duration longer than 120 ms. During a mean follow-up of 8 ± 2 mo, 665 transmissions were collected. No deaths or HF hospitalizations occurred. The sensitivity and specificity of the partners-HF algorithm for active clinical actions oriented to treat impending HF were 96.9% (95%CI: 0.96-0.98) and 92.5% (95%CI: 0.90-0.94) respectively. The positive and negative predictive values were 84.6% (95%CI: 0.82-0.87) and 98.6% (95%CI: 0.98-0.99) respectively. The partners-HF algorithm had an accuracy of 93.8% (95%CI: 0.92-0.96) in determining active clinical actions. With regard to active clinical actions, care alert had a sensitivity and specificity of 11.05% (95%CI: 0.09-0.13) and 93.6% respectively (95%CI: 0.92-0.95). The positive predictive value was 42.3% (95%CI: 0.38-0.46); the negative predictive value was 71.1% (95%CI: 0.68-0.74). Care alert had an accuracy of 68.9% (95%CI: 0.65-0.72) in determining active clinical actions.
Conclusion:
The partners-HF algorithm proved higher accuracy and sensitivity than care alert in determining active clinical actions oriented to treat impending HF. Future studies in larger populations should evaluate partners-HF ability to improve HF-related clinical outcomes.