Related Experiment Video
Updated: Mar 27, 2026

Troubleshooting FoCUS Image Acquisition: Patient Positioning, Transducer Manipulation, and Image Optimization
Published on: March 3, 2023
Optimal fluoroscopic viewing angles of left-sided heart structures in patients with aortic stenosis and mitral
Marco Spaziano1, Pascal Thériault-Lauzier1, Nicholas Meti1
1Department of Medicine, Division of Cardiology, McGill University Health Centre, Montreal, Quebec, Canada.
Background:
Transcatheter interventions are currently undertaken using "generic" fluoroscopic viewing angles. However, the position and orientation of heart structures may vary across patients and disease-specific remodeling processes.
Objective:
This study uses multislice computed tomography to determine optimal fluoroscopic viewing angles of the aortic and mitral annuli, the left atrial appendage and the atrial septum. We explored differences between patients with severe aortic stenosis (AS) and severe mitral regurgitation (MR).
Methods And Results:
The multislice computed tomographies of 28 patients with severe aortic stenosis (AS) and 32 patients with severe functional mitral regurgitation (MR) were analyzed. For each patient, we evaluated the optimal fluoroscopic viewing angles of the aortic and mitral annuli (en face, maximal and minimal diameters, aortic root with right, left and non coronary sinus in center), left atrial appendage orifice (en face, maximal and minimal diameters), and atrial septum (fossa ovalis) en face. The TAVR implantation view with right coronary sinus in center was LAO 9 - CRA 0 in the AS group and LAO 6 - CAU 5 in the MR group (p = NS). AS and MR patients differed significantly with respect to the fluoroscopic angulation of the aortic annulus en face (8.3°), the aortic annulus maximal (17.7°) and minimal (18.5°) diameters, the mitral annulus aorto-mural diameter (11.3°), and the left atrial appendage orifice en face (11.1°) (all p-values<0.05).
Conclusion:
Optimal fluoroscopic viewing angles of left-sided structures vary considerably between patients. Multislice computed tomography is a valuable tool to determine the most procedurally relevant angulations, with the potential to optimize procedural safety, efficacy and duration.
More Related Videos
Related Concept Videos
Mitral Stenosis II: Clinical features and Diagnostic Tests
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Imaging Studies for Cardiovascular System V: CT
Mitral Regurgitation II: Clinical Features and Diagnostic Tests
Mitral Stenosis III: Medical Management
Mitral Stenosis I: Introduction

