Related Experiment Video
Updated: Mar 27, 2026

Non-invasive Assessment of Microvascular and Endothelial Function
Published on: January 29, 2013
Accuracy of reflectance photoplethysmography on detecting cuff-induced vascular occlusions
Abstract:
Photoplethysmography (PPG) is a noninvasive optical technique, which can also be used to derive important parameters other than arterial oxygen saturation (SpO2). In this work, the accuracy of the technique on detecting changes in blood perfusion during different levels of vascular occlusions has been explored. A dual-wavelength, reflectance PPG probe was applied on the left forearm of 10 healthy volunteers and raw PPG signals were acquired by a research PPG processing system. The raw PPG signals were separated into pulsatile AC and continuous DC PPG components. The signals were used to estimate SpO2 and changes in concentration of oxygenated, deoxygenated, and total haemoglobin. Different levels of occlusions, from 20 mmHg to total occlusion were induced by a pressure-cuff on the left arm. The system was able to indicate all the occlusions. In particular, the haemoglobin concentration changes estimated from PPG were in high agreement with Near Infrared Spectroscopy measurements.
More Related Videos
04:44Author Spotlight: Enhancing Vascular Function and Physical Capacity in Cardiovascular Disease Through Novel Interventions and NIRS Technology
Published on: March 22, 2024
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...