ARTSENSTouch--A portable device for evaluation of carotid artery stiffness
Abstract:
Arterial stiffness is recognized as an independent risk factor for cardiovascular events and has potential in vascular screening. We have developed 'ARTSENS(®)', an image free system for evaluation of vascular stiffness. Here, we present ARTSENSTouch, a portable device for evaluation of carotid artery stiffness in field settings. A technical validation of the device in comparison with reference ultrasound imaging system is presented. The validation study emulated constraints faced in evaluation of stiffness in field, such as measurement in sitting posture, use of brachial blood pressure for computations, limited time available for testing and lack of electrical power supply for instrument. The usability of the device and its accuracy, with respect to the reference ultrasound imaging system, was verified by conducting in-vivo measurements on 30 subjects. Stiffness measurements made using ARTSENS in sitting posture showed strong correlation with those obtained from the imaging system in supine posture. The repeatability of ARTSENS measurements was also found to be satisfactory.
Related Concept Videos
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...