Effect of downsampling and compressive sensing on audio-based continuous cough monitoring
Abstract:
This paper presents an efficient cough detection system based on simple decision-tree classification of spectral features from a smartphone audio signal. Preliminary evaluation on voluntary coughs shows that the system can achieve 98% sensitivity and 97.13% specificity when the audio signal is sampled at full rate. With this baseline system, we study possible efficiency optimisations by evaluating the effect of downsampling below the Nyquist rate and how the system performance at low sampling frequencies can be improved by incorporating compressive sensing reconstruction schemes. Our results show that undersampling down to 400 Hz can still keep sensitivity and specificity values above 90% despite of aliasing. Furthermore, the sparsity of cough signals in the time domain allows keeping performance figures close to 90% when sampling at 100 Hz using compressive sensing schemes.