The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
Published on: December 23, 2014
Measurement of Central Venous Pressure Using Ultrasound in Emergency Department
Ahmad Abbasian1, Hamideh Feiz Disfani2, Mohammad Afzalimoghaddam3
1Department of Emergency Medicine, Pre-Hospital Emergency Research Center, Imam Khomeini Hospital , Tehran University of Medical Sciences, Tehran, IR Iran.
Background:
In order to assessment of intravascular fluid measurement of central venous pressure (CVP) is used via central venous catheterization (CVC). This procedure is highly invasive and may cause serious complications such as pneumothorax, infection, hematoma and etc. It is so valuable procedure if we can uses a less invasive or noninvasive procedure to assess patients intravascular fluid in critical positions.
Objectives:
In this study, the ultrasound was used to measure the central venous pressure (CVP).
Patients And Methods:
In this study, patients with Central venous catheterization were selected using simple random sampling. The largest diameter of longitudinal, transverse views and the cross-section of inferior vena cava (IVC) and internal jugular vein (IJV) were measured using the ultrasound in the bedside of the patients. Central venous pressure was measured using routine methods. Correlations between variables were analyzed using SPSS and linear regression.
Results:
Twenty patients with the mean age of 60.3 were studied. The main reason for cardiac catheterization was shock. There are no relationship between anterior posterior diameter of inferior vena cava and CVP of patients (P = 0.257). The longest diameter of IVC in ultrasonographic transverse view had significant association with CVP of patients (P = 0.045) but in patients with BMI > 25 it was not significant. Cross section of internal jugular vein had significant association with CVP of patients (P = 0.003). Longitudinal diameter of internal jugular vein had no significant association with CVP of patients (P = 0.052), but transverse diameter of internal jugular generally had significant association with CVP of patients (P = 0.003). Cross section of internal jugular had significant association with CVP (P = 0.001).
Conclusions:
Noninvasive assessment of the patient hydration condition using the ultrasound is a simple and practicable measure in emergency. With regard to the considerations, it is possible to estimate CVP via diameter measurement and cross-section of the central veins.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Measurement of Blood Pressure
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...