Monothermal Caloric Screening to Improve Healthcare Value
Related Experiment Video
Updated: Mar 27, 2026

Esophageal Heat Transfer for Patient Temperature Control and Targeted Temperature Management
Published on: November 21, 2017
Aaron L Thatcher1, Margot L Beckerman, Steven A Telian
1University of Michigan, Ann Arbor, Michigan, USA.
Objectives:
To evaluate whether monothermal caloric screening can reduce the number of caloric irrigations required in the vestibular testing battery while maintaining diagnostic accuracy.
Design:
Prospective controlled cohort study. Three hundred and ninety patients referred for vestibular testing at this tertiary referral health system over a 1-year period were evaluated; 24 patients met exclusion or failure criteria and 366 patients were included in the study. Population was 35.6% male; average age was 50.4 years old. Each patient underwent caloric testing using either warm or cool water irrigation initially and this data was used for monothermal screening data. All patients then completed bithermal binaural caloric testing to obtain the "gold standard" bithermal data for comparison. The sensitivity and specificity of monothermal cool or monothermal warm caloric tests were calculated using a receiver operating characteristic curve analysis.
Results:
Using a monothermal interear difference threshold of 25%, warm monothermal screening had sensitivity of 98.0%, specificity of 91.3%, false negative rate of 2%, and false positive rate of 8.7%. Cool monothermal screening also had excellent sensitivity (92.3%) and specificity (95.3)%, with a false negative rate of 7.7%, and a false positive rate of 4.7%. The diagnosis associated with the single false negative warm monothermal caloric test was compensated vestibular paresis. In the study population, 71.9% had a negative monothermal screen; if the monothermal data were accepted, 2 fewer irrigations would have been performed resulting in an average saving of $264 (typical Medicare reimbursement for 2 irrigations) billed per patient screened as well as shortening the average testing battery by about 15 min.
Conclusions:
Warm monothermal caloric screening can reduce time and cost of vestibular testing while nearly matching the diagnostic accuracy of bithermal testing.
More Related Videos
05:43Author Spotlight: Improving Lesion Contiguity in Pulmonary Vein Isolation via Proactive Esophageal Cooling
Published on: April 19, 2024
04:54Using a Combination of Indirect Calorimetry, Infrared Thermography, and Blood Glucose Levels to Measure Brown Adipose Tissue Thermogenesis in Humans
Published on: June 2, 2023
Related Concept Videos
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Decreased Body Temperature