Related Experiment Video
Updated: Mar 27, 2026

Increasing Pulmonary Artery Pulsatile Flow Improves Hypoxic Pulmonary Hypertension in Piglets
Published on: May 11, 2015
Echocardiographic Assessment of Pulmonary Arteries Pulsatility Index in Fontan Circulation
Reza Shabanian1, Mohammad Reza Mirzaaghayan2, Minoo Dadkhah1
1Department of Pediatric Cardiology, Children's Medical Center, Tehran University of Medical Sciences, Tehran, Iran.
Background:
Late complications after Fontan procedure may be due to the absence of pump and pulsatile pulmonary blood flow in this type of palliation. Our aim was to quantify the degree of pulsation by echocardiographic method in patients with extracardiac total cavopulmonary connection (ECTCPC) in comparison with biventricular circulation and few cases of pulsatile Fontan.
Methods:
In a case series study, pulsatility index (PI) derived by echocardiographic method were compared between 20 patients with ECTCPC, 6 patients with pulsatile Fontan and 18 normal individual aged 4 to 20 years old. All patients were in New York Heart Association class of I and there was no report of complication.
Results:
In patients with ECTCPC pulmonary artery branches Doppler flow study showed lower peak and mean velocities compared to the pulsatile Fontan and normal groups. ECTCPC patients had PI of 0.59 ± 0.14 and 0.59 ± 0.09 for right and left pulmonary arteries (RPA and LPA) respectively. PI was higher in patients with preserved antegrade flow (RPA PI = 0.94 ± 0.26, LPA PI = 0.98 ± 0.27) and in normal individuals (RPA PI = 1.59 ± 0.12, LPA PI = 1.64 ± 0.17) for both branches (p = 0.000).
Conclusion:
Using a Doppler derived index for pulsatility, patients with ECTCPC had the least pulsation. The pulmonary artery flow pattern in patients with preserved antegrade flow showed higher pulsatility indices in both branches. Normal individuals had the greatest pulsatility index.
More Related Videos
09:31Hemodynamic Precision in the Neonatal Intensive Care Unit using Targeted Neonatal Echocardiography
Published on: January 27, 2023
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Related Concept Videos
Pulse
The pulse serves as a clinical...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Aortic Regurgitation II: Clinical Features and Diagnostic Tests