Assessment of Child Anthropometry in a Large Epidemiologic Study
Published on: February 2, 2017
Identifying the optimal hand placement site for chest compression by measuring hand width and sternal length in young
Hanbyul Choi1, Christopher C Lee2, Ho Jung Kim3
1School of Medicine, St. George's University, Grenada, West Indies.
Objective:
There are no specific guidelines regarding the exact hand placement location for effective chest compressions. This study was designed to identify the optimal hand placement site over the chest during cardiopulmonary resuscitation (CPR).
Methods:
The sternal length (SL) of young Korean adults was measured as the distance from the suprasternal notch (SN) to the lower end of the sternum. In addition, the heel width of the hand (H) was measured 1 cm (H1) and 2 cm (H2) distal to the proximal end of the carpal bones.
Results:
A total of 300 men and 300 women were enrolled. SL positively correlated with height (R(2)=14.2), weight (R(2)=15.3), BMI (R(2)=10.3), H1 (R(2) =3.4), and H2 (R(2) = 5.0). Mean H2 and half of the SL (SL/2) for the subgroups were M 8.4 and 10.1 cm, M' 8.3 and 9.7 cm, W 7.6 and 10.1 cm, and W' 7.4 and 9.5 cm, respectively (M, men taller than the mean; M', men shorter than the mean; W, women taller than the mean; W', women shorter than the mean). Mean H2 in men was 1.1 to 1.6 cm shorter than SL/2, whereas mean H2 in women was 2.2 to 2.9 cm shorter than SL/2.
Conclusions:
To find the most optimal chest compression point, from the patients' left side, CPR providers need to palpate the SN using the right little finger and placing the left heel one heel width (H2) from the SN. From the patient's right side, CPR providers should use the left little finger to palpate the SN and place the right heel one heel width (H2) from the SN.
More Related Videos
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
10:07Measurement of Dynamic Scapular Kinematics Using an Acromion Marker Cluster to Minimize Skin Movement Artifact
Published on: February 10, 2015
Related Concept Videos
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Cardiopulmonary Resuscitation I: Adult
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pulse Assessment Sites
Assessment of blood pressure in brachial artery(two-step method)