Back-Analyses of Landfill Instability Induced by High Water Level: Case Study of Shenzhen Landfill
Ren Peng1, Yujing Hou2, Liangtong Zhan3
1Department of Civil Engineering, Beihang University, No.37 Xue-Yuan Road, Beijing 100191, China. pengfaren@163.com.
Abstract:
In June 2008, the Shenzhen landfill slope failed. This case is used as an example to study the deformation characteristics and failure mode of a slope induced by high water levels. An integrated monitoring system, including water level gauges, electronic total stations, and inclinometers, was used to monitor the slope failure process. The field measurements suggest that the landfill landslide was caused by a deep slip along the weak interface of the composite liner system at the base of the landfill. The high water level is considered to be the main factor that caused this failure. To calculate the relative interface shear displacements in the geosynthetic multilayer liner system, a series of numerical direct shear tests were carried out. Based on the numerical results, the composite lining system simplified and the centrifuge modeling technique was used to quantitatively evaluate the effect of water levels on landfill instability.
Related Concept Videos
Design Example: Analyzing Capacity Contours for Flood Risk Assessment
Design Example: Maintaining Level of an Embankment
Shrinkage in Concrete
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...
Design Example: Creating a Hydraulic Model of a Dam Spillway
Unsoundness of Aggregate due to Volume Change