Nikolay Boychev1, Deborah S Laughton1, Gulshan Bharwani1
1Ophthalmic Research Group, School of Life and Health Sciences, Aston University, Birmingham, United Kingdom.
Summary
Initial HEMA and silicone-hydrogel contact lens fit predicts long-term wear. Poor lens movement or recovery after 10 minutes suggests rejection for better patient comfort and vision.
Area of Science:
- Ophthalmology
- Biomaterials Science
Background:
- Contact lens fit is crucial for wearer comfort and visual acuity.
- Understanding how initial lens fit correlates with end-of-day performance is essential for prescribing practices.
Purpose of the Study:
- To evaluate the relationship between initial contact lens fit and end-of-day fit for both HEMA (hydrogel) and silicone-hydrogel (SiHy) lenses.
- To determine if early indicators of lens fit can predict long-term wearability.
Main Methods:
- Thirty participants were fitted with HEMA and SiHy lenses contralaterally.
- Key fit parameters (centration, lag, movement, recovery speed) were measured at multiple time points up to 8 hours.
- Corneal topography and tear break-up time were assessed pre-wear; comfort was self-reported.
Main Results:
- Comfort and centration were similar between HEMA and SiHy lenses, though comfort decreased over time.
- HEMA lenses exhibited greater movement on blink and lag compared to SiHy lenses.
- Early indicators of lens movement and recovery speed (after 10-20 minutes) predicted 8-hour wear performance for both lens types.
Conclusions:
- Initial assessment of contact lens movement and recovery speed is critical for predicting 8-hour wear.
- Contact lenses demonstrating poor movement or slow recovery after 10-20 minutes of wear should be considered for rejection to ensure optimal patient outcomes.
Related Concept Videos
Ophthalmic Drug Delivery Systems
211
Ophthalmic drug delivery faces major limitations due to poor absorption across the corneal membrane. This process is primarily driven by diffusion and is influenced by two main factors: the physicochemical properties of the drug and tear drainage. Most ophthalmic drugs, such as pilocarpine, epinephrine, atropine, and local anesthetics, are weak bases. They are typically formulated at an acidic pH to enhance chemical stability. However, this leads to high ionization, reducing their ability to...
211
Focusing of Light in the Eye
7.3K
Light rays enter the eye through the cornea, a transparent dome-shaped tissue that is the eye's outermost layer. The cornea bends or refracts, light rays traveling to the pupil. The shape of the cornea determines how much of the light is bent and whether the image will be focused correctly on the retina at the back of the eye. Once the light has passed through both refraction layers, it converges into a single focal point onto a small area. This is where photoreceptors start transforming...