Related Experiment Video
Updated: Mar 26, 2026

A Postoperative Evaluation Guideline for Computer-Assisted Reconstruction of the Mandible
Published on: January 28, 2020
Evaluation of computer-assisted mandibular reconstruction with vascularized fibular flap compared to conventional
Lei Zhang1, Zhixu Liu1, Biao Li1
1Department of Oral and Cranio-Maxillofacial Science, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai Key Laboratory of Stomatology, Shanghai, China.
Objective:
The purpose of this study was to evaluate the accuracy of computer-assisted mandibular reconstruction with a vascularized fibular flap and compare it with conventional surgery.
Study Design:
In this retrospective study conducted between February 2009 and December 2012, 8 patients underwent computer-assisted mandibular reconstruction, and 14 patients underwent conventional surgery. The accuracy of virtual surgical planning was determined, and the outcomes in the two groups were compared.
Results:
In the computer-assisted group, the deviation in fibula segment length was 1.34 ± 1.09 mm, the angular deviation was 2.29 ± 1.19°, and the mean 3-D deviation was 0.53 ± 0.06 mm. Mean differences in intercondylar distance, intergonial angle distance, anteroposterior distance, gonial angle, and duration of ischemia were all improved in the computer-assisted group compared with the conventional surgery group.
Conclusions:
Computer-assisted surgery, including preoperative virtual surgical planning, intraoperative cutting and reconstructive guides, and postoperative analysis is highly accurate in fibular flap mandibular reconstruction.