[The Time Sequence Noise Characteristics of the X- ray Fluoroscopic Image]
Takayoshi Umehara1, Kazuma Matsumoto, Tomoko Fujita
1Department of Radiological Technology, Hyogo College of Medicine College Hospital.
Abstract:
The role of the X-ray fluoroscopic image during interventional radiology (IVR) is not only the real-time dynamic image for the catheter operation but also to confirm the vascular anatomy using stored image, so that the importance increases more. For the purpose of measuring the time sequence characteristics of X-ray fluoroscopic image, we sampled the digital value of the same coordinate from each X-ray fluoroscopic image and calculated the frequency properties of the noise for the time sequence order as NPStime by performing Fourier transform on the digital value. The parameters, except k-factor which is the time sequence filter, did not influence NPStime. NPStime, which was examined in this study, showed that it is valuable for the method to analyze the time sequence noise characteristics. And, it also showed that it is possible to evaluate the time sequence image processing parameters of X-ray fluoroscopic image by NPStime. Nowadays, each manufacture of the X-ray angiographic system performs the original image processing to their own X-ray fluoroscopic images. The results of the discussion in this study could show the quantitative analysis on the frequency modulation. And it is possible to calculate NPStime by measuring the digital value of stored X-ray fluoroscopic image. The analysis by this method is also technically convenient for the time sequence noise characteristics of the X-ray fluoroscopic image.
More Related Videos
Related Concept Videos
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Basic Discrete Time Signals
The unit impulse or sample sequence is mathematically expressed as zero for all n values except at n=0, where it is one. The unit impulse sequence, denoted by δ(n), is the first difference of the unit step sequence, while the unit step sequence u(n) is the...