Related Experiment Video
Updated: Mar 26, 2026

Author Spotlight: Enhancing Small Animal Bone Compression Testing for Research
Published on: December 1, 2023
Failure of the human lumbar motion-segments resulting from anterior shear fatigue loading
Daniel M Skrzypiec1, Katrin Nagel, Kay Sellenschloh
1Leeds Institute of Rheumatic and Musculoskeletal Medicine, University of Leeds, U.K.
Abstract:
An in-vitro experiment was designed to investigate the mode of failure following shear fatigue loading of lumbar motion-segments. Human male lumbar motion-segments (age 32-42 years, n=6) were immersed in Ringer solution at 37°C and repeatedly loaded, using a modified materials testing machine. Fatigue loading consisted of a sinusoidal shear load from 0 N to 1,500 N (750 N±750 N) applied to the upper vertebra of the motion-segment, at a frequency of 5 Hz. During fatigue experiments, several failure events were observed in the dynamic creep curves. Post-test x-ray, CT and dissection revealed that all specimens had delamination of the intervertebral disc. Anterior shear fatigue predominantly resulted in fracture of the apophyseal processes of the upper vertebrae (n=4). Exposure to the anterior shear fatigue loading caused motion-segment instability and resulted in vertebral slip corresponding to grade I and 'mild' grade II spondylolisthesis, as observed clinically.
Related Concept Videos
Eccentric Axial Loading in a Plane of Symmetry
Unsymmetric Loading of Thin-Walled Members
The concept of the shear center is crucial in countering the...
Fatigue