Rapid scan electron paramagnetic resonance at 1.0 GHz of defect centers in γ-irradiated organic solids

Yilin Shi1, George A Rinard2, Richard W Quine2

  • 1Department of Chemistry and Biochemistry, University of Denver, Denver, CO 80208.

Radiation Measurements
|February 3, 2016
PubMed

Related Concept Videos

Electron Paramagnetic Resonance (EPR) Spectroscopy: Organic Radicals01:17

Electron Paramagnetic Resonance (EPR) Spectroscopy: Organic Radicals

Ideally, an unpaired electron shows a single peak in the EPR spectrum due to the transition between the two spin energy states. However, coupling interactions can occur between the spins of the unpaired electron and any neighboring spin-active nuclei. This hyperfine coupling results in hyperfine splitting, where the EPR signal is split into multiplets. The signals split into 2nI + 1 peaks, where n is the number of equivalent nuclei and I is the nuclear spin. These splitting patterns provide...
3.7K
Scanning Electron Microscopy01:07

Scanning Electron Microscopy

A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
5.9K
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
1.1K
Atomic Emission Spectroscopy: Lab01:29

Atomic Emission Spectroscopy: Lab

AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
783