Related Experiment Video
Updated: Mar 26, 2026

Intra-Operative Neural Monitoring of Thyroid Surgery in a Porcine Model
Published on: February 11, 2019
Verification of endotracheal tube placement using electrical stimulation through electrodes placed on the
1Department of Emergency Medicine, Chonnam National University Medical School, Gwangju, Korea.
Background:
Current methods for verification of endotracheal intubation can fail, particularly in emergency settings. We investigated whether a verification method using electrical stimulation through electrodes placed on the endotracheal tube cuff could distinguish endotracheal and esophageal intubations in an experimental setting.
Methods:
During three sequential sessions simulating emergency intubation without paralysis, rapid sequence intubation (RSI) with neuromuscular blockade, and intubation during cardiopulmonary resuscitation, eight pigs were intubated with an endotracheal tube fitted with two electrodes exposed on the cuff of the tube, first in the esophagus and next in the trachea or in reverse sequence. Cuff pressure was monitored during a 5-s electrical stimulation (20 mA, 80 Hz, 500 μs), and delta pressure was calculated as the difference between baseline cuff pressure and maximum cuff pressure during the electrical stimulation.
Results:
Delta pressure was significantly higher in esophageal than in tracheal placements in all three sequential sessions (86.0 [78.3-89.7] vs. 6.5 [2.0-7.9] mmHg, P = 0.001; 16.6 [13.2-22.8] vs. 0.8 [0.3-2.6] mmHg, P = 0.004; 66.1 [60.0-84.7] vs. 2.7 [0.7-9.7] mmHg, P = 0.001). The delta pressure did not overlap between tracheal and esophageal intubations except for the session simulating RSI with neuromuscular blockade, in which one of eight esophageal placements showed a delta pressure within the delta pressure range of tracheal placements.
Conclusion:
Electrical stimulation through electrodes placed on the endotracheal tube cuff produced remarkably greater increases in cuff pressure in esophageal intubations than in tracheal intubations in an experimental setting.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...

