Related Experiment Video
Updated: Mar 26, 2026

A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Simple, quantitative method for low molecular weight dissolved organic matter extracted from natural waters based
Alfonso Rojas1, Sara Sandron1, Richard Wilson2
1Australian Centre for Research on Separation Sciences (ACROSS), School of Physical Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania, 7001, Australia.
Abstract:
A simple, high-performance counter-current chromatography method with sequential UV absorbance (254 nm) and evaporative light scattering detection (ELSD) was developed for the quantification of pre-extracted low molecular weight dissolved organic matter (DOM) extracted from natural waters. The method requires solid-phase extraction (SPE) extraction of only small volumes of water samples, here using poly(styrenedivinylbenzene)-based extraction cartridges (Varian PPL). The extracted and concentrated DOM was quantified using reversed-phase high-performance counter-current chromatography (HPCCC), with a water/methanol (5:5) mobile phase and hexane/ethyl acetate (3:7) stationary phase. The critical chromatographic parameters were optimised, applying a revolution speed of 1900 rpm and a flow-rate of 1 mL min(-1). Under these conditions, 50 μL of extracted DOM solution could be injected and quantified using calibration against a reference natural dissolved material (Suwannee River), based upon UV absorbance at 254 nm and ELSD detection. Both detection methods provided excellent linearity (R(2) > 0.995) for DOM across the concentration ranges of interest, with limits of detection of 4 μg ml(-1) and 7 μg ml(-1) for ELSD and UV absorbance, respectively. The method was validated for peak area precision (<5%), and accuracy and recovery based upon spiking seawater samples prior to extraction, together with DOM solutions post-extraction (>95% recovery). The developed method was applied to the determination of the concentration of DOM in seawater, based upon initial sample volumes as small as 20 mL.
More Related Videos
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...