Related Experiment Video
Updated: Mar 26, 2026

Resolving Affinity Purified Protein Complexes by Blue Native PAGE and Protein Correlation Profiling
Published on: April 1, 2017
Use of Time-Resolved Fluorescence To Improve Sensitivity and Dynamic Range of Gel-Based Proteomics
AnnSofi Sandberg1, Volker Buschmann2, Peter Kapusta2
1Respiratory Medicine Unit, Department of Medicine, Center for Molecular Medicine, Karolinska Institutet , 171 76 Stockholm, Sweden.
Abstract:
Limitations in the sensitivity and dynamic range of two-dimensional gel electrophoresis (2-DE) are currently hampering its utility in global proteomics and biomarker discovery applications. In the current study, we present proof-of-concept analyses showing that introducing time-resolved fluorescence in the image acquisition step of in-gel protein quantification provides a sensitive and accurate method for subtracting confounding background fluorescence at the photon level. In-gel protein detection using the minimal difference gel electrophoresis workflow showed improvements in lowest limit of quantification in terms of CyDye molecules per pixel of 330-fold in the blue-green region (Cy2) and 8000-fold in the red region (Cy5) over conventional state-of-the-art image acquisition instrumentation, here represented by the Typhoon 9400 instrument. These improvements make possible the detection of low-abundance proteins present at sub-attomolar levels, thereby representing a quantum leap for the use of gel-based proteomics in biomarker discovery. These improvements were achieved using significantly lower laser powers and overall excitation times, thereby drastically decreasing photobleaching during repeated scanning. The single-fluorochrome detection limits achieved by the cumulative time-resolved emission two-dimensional electrophoresis (CuTEDGE) technology facilitates in-depth proteomics characterization of very scarce samples, for example, primary human tissue materials collected in clinical studies. The unique information provided by high-sensitivity 2-DE, including positional shifts due to post-translational modifications, may increase the chance to detect biomarker signatures of relevance for identification of disease subphenotypes.
Related Concept Videos
Protein Dynamics in Living Cells
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...