Simultaneous Electrocardiography Recording and Invasive Blood Pressure Measurement in Rats
Published on: January 31, 2019
Assessing the eligibility of a non-invasive continuous blood pressure measurement technique for application during
Objective:
To assess the eligibility for replacement of invasive blood pressure as measured "within" the arterial vessel (IBP) with non-invasive continuous arterial blood pressure (cNIP) monitoring during total intravenous anaesthesia (TIVA), the ability of cNiP to track fast blood pressure changes needs to be quantified. A new method of statistical data analysis is developed for this purpose.
Methods:
In a pilot study on patients undergoing neurosurgical anaesthesia, mean arterial pressure MAPIBP measured with IBP was compared to MAPCNP measured by the CNAP Monitor 500 in ten patients (age: 63±13 a). Correlation analysis of changes of device differences ΔeMAP=ΔMAPCNP-ΔMAPIBP with changes of MAPIBP (ΔMAPIBP) during intervals of vasoactivity was conducted. An innovative technique, of linear trend analysis (LTA) applied to two signals, is described to perform this analysis without a priori knowledge of intervals of vasoactivity.
Results:
Analysis of ΔeMAP during vasoactivity revealed that ΔMAPCNP systematically underestimated ΔMAPIBP by 37%. This was confirmed in the complete data set using LTA technique showing a systematic, yet patient specific, underestimation in tracking ΔMAPIBP (16…120%).
Conclusion:
The proposed LTA technique is able to detect systematic errors in tracking short-term blood pressure changes otherwise masked by established analysis. LTA may thus be a useful tool to assess the eligibility of cNIP to replace IBP during TIVA.
More Related Videos
Related Concept Videos
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: