Related Experiment Video
Updated: Mar 25, 2026

An Intestine/Liver Microphysiological System for Drug Pharmacokinetic and Toxicological Assessment
Published on: December 3, 2020
Forced degradation of nepafenac: Development and validation of stability indicating UHPLC method
Mislav Runje1, Sandra Babić2, Ernest Meštrović1
1Pliva Croatia TAPI R&D, Prilaz baruna Filipovića 25, 10000 Zagreb, Croatia.
Abstract:
This paper presents stability study of the nonsteroidal anti-inflammatory drug (NSAID) nepafenac. In order to investigate stability of nepafenac, it was subjected to forced degradation under different stress conditions: acid and base hydrolysis, oxidation, humidity, heat and light. A novel stability indicating reverse phase ultra high performance liquid chromatographic (UHPLC) method coupled to ultraviolet detector has been developed to separate nepafenac and all related compounds (2-aminobenzophenone, Cl-thionepafenac, thionepafenac, Cl-nepafenac, hydroxy-nepafenac, and cyclic-nepafenac). Efficient chromatographic separation was achieved on a Waters Acquity BEH C18 stationary phase with a gradient elution. Quantification was carried out at 235 nm at a flow rate of 0.6 mL/min(-1). The resolution between nepafenac and six potential impurities is found to be greater than 2.0. The developed method was validated with respect to specificity, LOD, LOQ, linearity, precision, accuracy and robustness. The r(2) values for nepafenac and six potential impurities were all greater than 0.999. The developed method is capable to detect impurities of nepafenac at a level of 0.005% with respect to test concentration of 1.0mg/mL. Significant degradation is observed in acid, base and oxidative degradation conditions and degradation products (DPs) were identified using mass spectrometry analysis; two of them were found to be a known process related impurities (hydroxy- and cyclic-nepafenac) whereas four degradation products were identified as new degradation impurities. The forced degradation samples were assayed against a qualified reference standard and the mass balance was found to be close to 99.5%.
More Related Videos
11:18Isolation and Preparation of Bacterial Cell Walls for Compositional Analysis by Ultra Performance Liquid Chromatography
Published on: January 15, 2014
10:13Author Spotlight: An Efficient Methodology to Confidently Differentiate and Characterize Fentanyl Analogs
Published on: November 8, 2024
Related Concept Videos
Drug Product Stability
Pharmaceutical Alternatives: Stability-Related Therapeutic Nonequivalence