Related Experiment Video
Updated: Mar 25, 2026

Author Spotlight: An Efficient Methodology to Confidently Differentiate and Characterize Fentanyl Analogs
Published on: November 8, 2024
Simultaneous determination of corynoline and acetylcorynoline in human urine by LC-MS/MS and its application to a
Ruijuan Liu1, Lu Zheng2, Minlu Cheng1
1Department of Pharmaceutical Analysis, China Pharmaceutical University, 24 Tongjiaxiang, Nanjing 210009, China; Nanjing Clinical Tech Laboratories Inc., 18 Zhilan Road, Jiangning District, Nanjing 211000, China.
Abstract:
Corynoline and acetycorynoline, the major active components derived from Corydalis bungeana Herba, showed multiple pharmacological activities. However, quantification of the two compounds in human urine has not been reported. A simple liquid chromatography with tandem mass spectrometry method for the simultaneous determination of corynoline and acetycorynoline in human urine has been developed and fully validated. The analytes were extracted from urine samples by simple liquid-liquid extraction. Chromatographic separation was achieved on a Hedera ODS-2C18 column with the mobile phase of water (containing 0.5% formic acid) and acetonitrile (28:72, v/v) at a flow rate of 0.4mL/min. A tandem mass spectrometric detection was conducted using multiple reaction monitoring via an electrospray ionization source in positive mode. The monitored ion transitions were m/z 368.1→289.1 for corynoline, m/z 410.2→289.2 for acetycorynoline and m/z 380.2→243.2 for donepezil (internal standard), respectively. The calibration curves were linear (correlation coefficients>0.9970) over the concentration ranges of 3.0-3000pg/mL for corynoline and 3.0-1000pg/mL for acetycorynoline. The established method was highly sensitive with the lower limit of quantification (LLOQ) of 3.0pg/mL for both analytes. The intra- and inter-day precision was lower than 10% in terms of relative standard deviation for the low, medium, and high quality control samples, and lower than 16% for the LLOQ samples of the analytes. The accuracy was within ±10% in terms of relative error for both analytes. The method was successfully applied to a urinary excretion study after oral administration of the Chinese medicine formula Shuanghua Baihe tablets in healthy volunteers. The urinary excretion profiles of corynoline and acetycorynoline in human were first reported. The results of this study suggest that renal excretion was not the main excretion pathway of corynoline and acetycorynoline in humans.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
10:38Simultaneous Quantification of Selected Kynurenines Analyzed by Liquid Chromatography-Mass Spectrometry in Medium Collected from Cancer Cell Cultures
Published on: May 9, 2020