Related Experiment Video
Updated: May 5, 2026

Preparation of Graphene Liquid Cells for the Observation of Lithium-ion Battery Material
Published on: February 5, 2019
In Situ Visualization of Lithium Ion Intercalation into MoS2 Single Crystals using Differential Optical Microscopy
Mukkannan Azhagurajan1, Tetsuya Kajita2, Takashi Itoh2
1Institute of Multidisciplinary Research for Advanced Materials, Tohoku University , 2-1-1 Katahira, Sendai 980-8577, Japan.
Abstract:
Atomic-level visualization of the intercalation of layered materials, such as metal chalcogenides, is of paramount importance in the development of high-performance batteries. In situ images of the dynamic intercalation of Li ions into MoS2 single-crystal electrodes were acquired for the first time, under potential control, with the use of a technique combining laser confocal microscopy with differential interference microscopy. Intercalation proceeded via a distinct phase separation of lithiated and delithiated regions. The process started at the atomic steps of the first layer beneath the selvedge and progressed in a layer-by-layer fashion. The intercalated regions consisted of Li-ion channels into which the newly inserted Li ions were pushed atom-by-atom. Interlayer diffusion of Li ions was not observed. Deintercalation was also clearly imaged and was found to transpire in a layer-by-layer mode. The intercalation and deintercalation processes were chemically reversible and can be repeated many times within a few atomic layers. Extensive intercalation of Li ions disrupted the atomically flat surface of MoS2 because of the formation of small lithiated domains that peeled off from the surface of the crystal. The current-potential curves of the intercalation and deintercalation processes were independent of the scan rate, thereby suggesting that the rate-determining step was not governed by Butler-Volmer kinetics.
More Related Videos
11:03Nanoscale Characterization of Liquid-Solid Interfaces by Coupling Cryo-Focused Ion Beam Milling with Scanning Electron Microscopy and Spectroscopy
Published on: July 14, 2022
09:41Using Laser Scanning Microscopy to Determine Electromigration in Molybdenum Disilicide
Published on: May 23, 2025
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Atomic Force Microscopy
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...