Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

625
DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
625
Imaging Studies I: CT and MRI01:14

Imaging Studies I: CT and MRI

1.1K
Introduction: MRI and CT scans are crucial advancements in medical imaging techniques, playing a vital role in diagnosing conditions related to the gastrointestinal (GI) system. Each scan serves distinct purposes, targets specific areas, and requires unique nursing duties.
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
1.1K
Computed Tomography01:10

Computed Tomography

9.5K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
9.5K
Imaging Studies VII: Vascular Imaging01:19

Imaging Studies VII: Vascular Imaging

459
DefinitionRenal angiography, also known as renal arteriography, is an imaging technique used to obtain a comprehensive view of blood flow and the vascular structure of blood vessels in the kidneys and surrounding areas.PurposeRenal angiography detects blood vessel abnormalities in the kidneys, such as aneurysms, stenosis, thrombosis, vascular tumors, and renal artery stenosis. It evaluates kidney function and guides interventional treatments like angioplasty or stent placement.Pre-Procedure...
459
Imaging Studies for Cardiovascular System V: CT01:28

Imaging Studies for Cardiovascular System V: CT

536
Cardiac computed tomography (CT) scanning is an advanced cardiac imaging technique that utilizes CT technology, with or without intravenous (IV) contrast, to produce accurate cross-sectional virtual slices of specific areas of the heart, coronary circulation, and major blood vessels such as the aorta, pulmonary veins, and arteries. The computer processes these slices to generate three-dimensional images. Multidetector CT (MDCT) is a rapid form of CT scanning that captures multiple slices...
536
Imaging Studies for Cardiovascular System IV: CMRI01:21

Imaging Studies for Cardiovascular System IV: CMRI

515
Cardiovascular magnetic resonance imaging, or CMRI, is a non-invasive diagnostic test that employs a magnetic field and radiofrequency waves to create precise images of the heart and arteries. It provides comprehensive information about cardiac anatomy, function, perfusion, and tissue characterization without ionizing radiation.IndicationsCMRI diagnoses various heart conditions, including tissue damage from heart attacks, ischemic heart disease, myocarditis, aortic issues (tears, aneurysms,...
515

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Identification and functional characteristics of key regulatory genes in Populus alba in response to cold stress.

Plant physiology and biochemistry : PPB·2026
Same author

Multi-Objective Optimization for Through-Silicon via Structure Considering Thermomechanical Reliability and Electrical Performance.

Micromachines·2026
Same author

Effects of salinity and fermentation time on the microbial community, flavor, and metabolites of shrimp paste.

Food research international (Ottawa, Ont.)·2026
Same author

GC-IMS combined with sensory and chemical analyses to reveal flavor and taste differences of antarctic krill paste under different processing conditions.

Frontiers in nutrition·2026
Same author

OmpK36 GD insertion induces RpoS-dependent <i>bla</i><sub>KPC</sub> overexpression in carbapenem-resistant <i>Klebsiella pneumoniae</i>.

Antimicrobial agents and chemotherapy·2026
Same author

Brain-heart interaction: direct and indirect circuits in health and diseases.

Journal of advanced research·2026

Related Experiment Video

Updated: Mar 25, 2026

Quantification of Optic Nerve Cross Sectional Area on MRI: A Novel Protocol using Fiji Software
08:57

Quantification of Optic Nerve Cross Sectional Area on MRI: A Novel Protocol using Fiji Software

Published on: September 4, 2021

4.6K

Imaging study on the optic canal using sixty four-slice spiral computed tomography.

Peng-Fei Jiang1, Xiu-Yu Dai1, Yongbin Lv2

  • 1Department of Ophthalmology, Yantai Yuhuangding Hospital, Affiliated Hospital of Medical College, Qingdao University Yantai 264000, P. R. China.

International Journal of Clinical and Experimental Medicine
|February 18, 2016
PubMed
Summary

64-slice spiral CT accurately images the optic canal, revealing the medial wall is longest. This advanced imaging technology provides precise measurements for anatomical studies.

Keywords:
64 slice spiralCTOptic canalimaging sectional anatomy

More Related Videos

Thinned-skull Cortical Window Technique for In Vivo Optical Coherence Tomography Imaging
07:28

Thinned-skull Cortical Window Technique for In Vivo Optical Coherence Tomography Imaging

Published on: November 19, 2012

15.8K
Assessment of Global Ocular Structure Following Spaceflight Using a Micro-Computed Tomography Micro-CT Imaging Method
09:11

Assessment of Global Ocular Structure Following Spaceflight Using a Micro-Computed Tomography Micro-CT Imaging Method

Published on: October 27, 2020

6.2K

Related Experiment Videos

Last Updated: Mar 25, 2026

Quantification of Optic Nerve Cross Sectional Area on MRI: A Novel Protocol using Fiji Software
08:57

Quantification of Optic Nerve Cross Sectional Area on MRI: A Novel Protocol using Fiji Software

Published on: September 4, 2021

4.6K
Thinned-skull Cortical Window Technique for In Vivo Optical Coherence Tomography Imaging
07:28

Thinned-skull Cortical Window Technique for In Vivo Optical Coherence Tomography Imaging

Published on: November 19, 2012

15.8K
Assessment of Global Ocular Structure Following Spaceflight Using a Micro-Computed Tomography Micro-CT Imaging Method
09:11

Assessment of Global Ocular Structure Following Spaceflight Using a Micro-Computed Tomography Micro-CT Imaging Method

Published on: October 27, 2020

6.2K

Area of Science:

  • Medical Imaging
  • Radiology
  • Anatomy

Background:

  • Multislice computed tomography (MSCT) technology has rapidly advanced, improving clinical imaging accuracy.
  • The 64-slice CT scanner offers enhanced temporal and spatial resolution for detailed imaging.

Purpose of the Study:

  • To evaluate the utility of 64-slice spiral computed tomography (CT) for imaging the normal optic canal.
  • Assessing the application of advanced CT technology in visualizing delicate anatomical structures.

Main Methods:

  • 100 healthy adult subjects were scanned using a 64-slice spiral CT scanner.
  • Detailed imaging, reconstruction, and examination of the optic canal were performed.

Main Results:

  • The medial wall of the optic canal was identified as the longest segment.
  • The superior and lateral walls were shorter than the medial wall, with the inferior wall being the shortest.
  • Imaging data obtained with 64-slice CT aligned with previous findings from other imaging modalities.

Conclusions:

  • 64-slice spiral CT is a valuable and accurate method for measuring optic canal wall lengths.