Preliminary Results From the C-Pulse OPTIONS HF European Multicenter Post-Market Study
Antonia Schulz1, Thomas Krabatsch2, Jan D Schmitto3
1Cardio Centrum Berlin, Academic Teaching Institution of Charité, Medical University Berlin, Berlin, Germany.
Abstract:
BACKGROUND The C-Pulse System is an extra-aortic balloon counterpulsation device. It is used to treat patients with heart failure disease in NYHA functional class III or ambulatory class IV. MATERIAL AND METHODS We present preliminary site-reported 6-month data from 3 centers in Germany as part of the prospective observational post-market OPTIONS HF study. RESULTS Between May 2013 and March 2014, the C-Pulse System was implanted in 8 patients (7 male) with a mean age of 61.6±9.3 years. Four had ischemic and 4 had non-ischemic cardiomyopathy. No stroke, myocardial infarction, major bleeding, or major infection due to the device were reported. One patient developed non-device-related refractory tachycardia with worsening heart failure 12 h after surgery and underwent left ventricular assist device implantation. Within 6 months of observation, functional status improved from NYHA III to II in 5 patients, and 2 remained in NYHA III. Mean left ventricular ejection fraction increased from 24.3±7.9% to 44.5±4.5% (p<0.0001). Mean Kansas City Cardiomyopathy Questionnaire overall score improved from 28.6±19.1 to 59.1±22.5 (p=0.0183). Six-minute walk test was performed in 6 out of 7 patients at follow-up. The mean distance improved from 252.0±85.1 m to 279.2±87.5 m (p>0.05). One patient was weaned off the device after 6 months of support. CONCLUSIONS The C-Pulse System provides a therapeutic option for patients with moderate-to-severe heart failure and seems to improve quality of life and cardiac function over time.
More Related Videos
03:47Author Spotlight: Workflow for Integrating POCUS Data into EHR for Managing Heart Failure Patients
Published on: July 12, 2024
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Pulse Assessment Sites
Clinical Trials: Overview
Clinical Trials
There are four phases in a clinical trial. A phase one...
Special considerations while measuring pulse