Comparison of objective refraction in darkness to cycloplegic refraction: a pilot study
Balamurali Vasudevan1, Kenneth J Ciuffreda2, Kelly Meehan3
1Midwestern University, Glendale, Arizona, USA. drmurali@gmail.com.
Clinical & Experimental Optometry
|February 19, 2016
Summary
Objective refraction in the dark using an open-field autorefractor is a reliable alternative to cycloplegic refraction in children and young adults. This method accurately measures refractive error without the need for cycloplegic eye drops.
Area of Science:
- Ophthalmology
- Optometry
- Vision Science
Background:
- Assessing refractive error in children and young adults often requires cycloplegic eye drops.
- Conventional methods include subjective refraction and retinoscopy under cycloplegia.
- Objective, non-cycloplegic methods are sought as potentially more convenient alternatives.
Purpose of the Study:
- To evaluate non-cycloplegic objective refraction in darkness using an open-field autorefractor.
- To compare this method with traditional distance cycloplegic subjective refraction and retinoscopy.
- To determine the reliability of the non-cycloplegic method in children and young adults.
Main Methods:
- Visually normal young adults (23-31 years) and children (5-12 years) participated.
- Refractive error was measured using three techniques: non-cycloplegic objective autorefraction in darkness, distance cycloplegic subjective refraction, and distance cycloplegic retinoscopy.
- All measurements were taken within a single session on the same day.
Main Results:
- No significant differences in spherical refractive component were found among the three techniques for either adults or children.
- High correlations were observed between non-cycloplegic objective refraction in the dark and both cycloplegic methods.
- Mean differences in spherical component were small, indicating good agreement between methods.
Conclusions:
- Non-cycloplegic objective refraction in darkness is comparable to conventional cycloplegic refraction methods.
- This technique shows high correlation with established methods in both pediatric and young adult populations.
- It may serve as a reliable adjunct or alternative to cycloplegic refraction.
Related Concept Videos
Focusing of Light in the Eye
7.2K
Light rays enter the eye through the cornea, a transparent dome-shaped tissue that is the eye's outermost layer. The cornea bends or refracts, light rays traveling to the pupil. The shape of the cornea determines how much of the light is bent and whether the image will be focused correctly on the retina at the back of the eye. Once the light has passed through both refraction layers, it converges into a single focal point onto a small area. This is where photoreceptors start transforming...
7.2K
Photoreceptors and Visual Pathways
10.9K
At the molecular level, visual signals trigger transformations in photopigment molecules, resulting in changes in the photoreceptor cell's membrane potential. The photon's energy level is denoted by its wavelength, with each specific wavelength of visible light associated with a distinct color. The spectral range of visible light, classified as electromagnetic radiation, spans from 380 to 720 nm. Electromagnetic radiation wavelengths exceeding 720 nm fall under the infrared category,...
10.9K
Properties of Enantiomers and Optical Activity
23.3K
It is essential to understand the difference between chiral and achiral interactions and the implications thereof in optical activity and their applications. Just as our feet, which are chiral, interact uniquely with chiral objects, such as a pair of shoes, but identically with achiral socks, enantiomers of a molecule exhibit different properties only when they interact with other chiral media. An example of a significant implication from this facet is the phenomenon known as optical activity,...
23.3K