Background:
The objective of this study was to evaluate performance metrics and associated patient outcomes of an automated surveillance system, the blood Nosocomial Infection Marker (NIM).
Methods:
We reviewed records of 237 patients with and 36,927 patients without blood NIM using the National Healthcare Safety Network (NHSN) definition for laboratory-confirmed bloodstream infection (BSI) as the gold standard. We matched cases with noncases by propensity score and estimated attributable mortality and cost of NHSN-reportable central line-associated bloodstream infections (CLABSIs) and non-NHSN-reportable BSIs.
Results:
For patients with central lines (CL), the blood NIM had 73.2% positive predictive value (PPV), 99.9% negative predictive value (NPV), 89.2% sensitivity, and 99.7% specificity. For all patients regardless of CL status, the blood NIM had 53.6% PPV, 99.9% NPV, 84.0% sensitivity, and 99.9% specificity. For CLABSI cases compared with noncases, mortality was 17.5% versus 9.4% (P = .098), and median charge was $143,935 (interquartile range [IQR], $89,794-$257,447) versus $115,267 (IQR, $74,937-$173,053) (P < .01). For non-NHSN-reportable BSI cases compared with noncases, mortality was 23.6% versus 6.7% (P < .0001), and median charge was $86,927 (IQR, $54,728-$156,669) versus $62,929 (IQR, $36,743-$115,693) (P < .0001).
Conclusions:
The NIM is an effective screening tool for BSI. Both NHSN-reportable and nonreportable BSI cases were associated with increased mortality and cost.
More Related Videos
11:25Preparation of a Blood Culture Pellet for Rapid Bacterial Identification and Antibiotic Susceptibility Testing
Published on: October 15, 2014
09:07Author Spotlight: Accelerating Diagnostic Accuracy with Direct Identification of Gram-Negatives from Blood Culture Bottles
Published on: May 24, 2024
Related Concept Videos
Automated Microbial Diagnostics
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...