Richard Ballas1,2, Philippe Teissier3,4, Jacques Teissier5
1Service de chirurgie orthopédique, Hôpital de Saint-Pierre, Université de La Réunion, BP 350, 97448, Saint-Pierre Cedex, Ile de La Réunion, France. richardballas@yahoo.fr.
Purpose:
When the proximal humeral anatomy is altered because of malunion, shoulder arthroplasty is a challenge for the orthopaedic surgeon, and tuberosity osteotomy should be avoided whenever possible. The purpose of this study was to investigate the clinical and radiological outcomes of anatomic stemless shoulder arthroplasty in cases of malunion. We hypothesized that a stemless prosthesis can be implanted without performing tuberosity osteotomy.
Methods:
We conducted a continuous, single surgeon, retrospective case series study with a minimum follow-up of two years (mean of 44 months, range 24-80). The Constant-Murley score, active range of motion and X-rays were evaluated in 27 patients (mean age of 60 years, range 37-83) with proximal humeral malunion who were treated with a stemless anatomic shoulder prosthesis.
Results:
In all patients, the prosthesis was implanted without the need for tuberosity osteotomy. The Constant score improved from 27 to 62 (p ≤ 0.001), active anterior elevation from 81° to 129° (p ≤ 0.001), and external rotation from 5° to 40° (p ≤ 0.001). There was no evidence of radiological loosening.