Related Experiment Video
Updated: Mar 25, 2026

Author Spotlight: Technologies and Challenges in Elemental Analysis of Food Samples
Published on: December 22, 2023
Empirical Approach for Estimating Reference Material Heterogeneity and Sample Minimum Test Portion Mass for "Nuggety"
L Paul Bédard1, Kim H Esbensen2, Sarah-Jane Barnes1
1Université du Québec à Chicoutimi , 555 boul. Université, Chicoutimi, Québec, Canada , G7H 2B1.
Abstract:
Quantification of precious metal content is important for studies of ore deposits, basalt petrogenesis, and precious metal geology, mineralization, mining, and processing. However, accurate determination of metal concentrations can be compromised by microheterogeneity commonly referred to as the "nugget effect", i.e., spatially significant variations in the distribution of precious metal minerals at the scale of instrumental analytical beam footprints. There are few studies focused on the spatial distribution of such minerals and its detrimental effects on quantification of the existing suite of relevant reference materials (RM). In order to assess the nugget effect in RM, pressed powder pellets of MASS-1, MASS-3, WMS-1a, WMS-1, and KPT-1 (dominantly sulfides) as well as CHR-Pt+ and CHR-Bkg (chromite-bearing) were mapped with micro-XRF. The number of verified nuggets observed was used to recalculate an effective concentration of precious metals for the analytical aliquot, allowing for an empirical estimate of a minimum mass test portion. MASS-1, MASS-3, and WMS-1a did not contain any nuggets; therefore, a convenient small test portion could be used here (<0.1 g), while CHR-Pt+ would require 0.125 g and WMS-1 would need 23 g to be representative. For CHR-Bkg and KPT-1, the minimum test portion mass would have to be ∼80 and ∼342 g, respectively. Minimum test portions masses may have to be greater still in order to provide detectable analytical signals. Procedures for counteracting the detrimental manifestations of microheterogeneity are presented. It is imperative that both RM and pristine samples are treated in exactly the same way in the laboratory, lest powders having an unknown nugget status (in effect all field samples for analysis) can not be documented to be representing a safe minimum mass basis.
More Related Videos
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015
05:04Determining the Mechanical Strength of Ultra-Fine-Grained Metals
Published on: November 22, 2021
Related Concept Videos
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Gravimetry: Overview
In precipitation gravimetry, the analyte is converted into a precipitate and weighed. For example, the silver content in a sample can be estimated by precipitating and...
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...
Sampling Methods: Overview
In analytical chemistry, the choice of...