Related Experiment Video
Updated: Mar 25, 2026

Use of MRI-ultrasound Fusion to Achieve Targeted Prostate Biopsy
Published on: April 9, 2019
Diffusion in prostate cancer detection on a 3T scanner: How many b-values are needed?
Thomas de Perrot1, Max Scheffler1, José Boto1
1Division of Radiology, Geneva University Hospitals, Geneva, Switzerland.
Including perfusion-sensitive apparent diffusion coefficient (ADC) maps and high b-value images like b1500 significantly improves prostate cancer detection using diffusion-weighted imaging (DWI). Using more than two b-values does not enhance diagnostic performance.
Area of Science:
- Radiology
- Oncology
- Medical Imaging
Background:
- Diffusion-weighted imaging (DWI) is crucial for prostate cancer detection.
- Apparent diffusion coefficient (ADC) maps are key metrics in DWI analysis.
- Understanding the impact of perfusion and b-values on ADC accuracy is essential for improving diagnostic performance.
Purpose of the Study:
- To evaluate how perfusion influences ADC maps in prostate cancer detection.
- To determine the optimal number and contribution of b-value images for DWI in prostate cancer diagnosis.
- To assess the efficacy of different ADC calculation methods and b-values.
Main Methods:
- 3T MRI with DWI using b-values of 0, 500, 1000, and 1500 s/mm² was performed on patients scheduled for prostatectomy.
- Monoexponential models were used to calculate ADC, with and without the b0 (perfusion-sensitive) component, and using two b-values.
- Histology-based segmentation defined tumoral and normal prostatic voxels, and areas under the receiver operating characteristic curves (AUC) were calculated.
Main Results:
- Perfusion-sensitive ADC maps (including b0) and ADC maps using b1500 showed improved performance in detecting prostate cancer compared to perfusion-insensitive maps.
- Models combining ADC with the b1500 image parameter significantly enhanced diagnostic performance (AUCs of 0.884 and 0.883).
- Using more than two b-values did not yield further improvements in AUC.
Conclusions:
- Incorporating the b0 value in ADC calculations generates superior ADC maps for prostate cancer detection.
- The b1500 image parameter, when combined with ADC, also enhances diagnostic performance.
- The study suggests that using more than two b-values offers no additional benefit for prostate cancer detection via DWI.
More Related Videos
06:08A Cognitive Fusion-guided Prostate Biopsy Using Multiparametric Magnetic Resonance Imaging and Transrectal Ultrasound
Published on: March 21, 2025
15:48Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014