Related Experiment Video
Updated: Mar 25, 2026

10:32
Monitoring Dynamic Growth of Retinal Vessels in Oxygen-Induced Retinopathy Mouse Model
Published on: April 2, 2021
4.4K
The Colorado-retinopathy of prematurity model (CO-ROP): postnatal weight gain screening algorithm
Jennifer H Cao1, Brandie D Wagner2, Emily A McCourt1
1Department of Ophthalmology, University of Colorado School of Medicine, Aurora.
Summary
A new retinopathy of prematurity (ROP) screening model, CO-ROP, uses birth weight, gestational age, and weight gain to maintain high sensitivity while reducing unnecessary screenings. This model improves specificity for detecting ROP in premature infants.
Area of Science:
- Neonatology
- Ophthalmology
- Perinatal Medicine
Background:
- Retinopathy of prematurity (ROP) is a leading cause of blindness in premature infants.
- Current screening guidelines (2013) for ROP have limitations in specificity, leading to over-screening.
- A more accurate and efficient screening model is needed to optimize ROP detection and resource allocation.
Purpose of the Study:
- To introduce and evaluate a novel screening model for ROP, termed CO-ROP.
- The CO-ROP model incorporates birth weight, gestational age, and postnatal weight gain.
- To assess if CO-ROP improves specificity in detecting all grades of ROP compared to existing 2013 guidelines while maintaining sensitivity.
Main Methods:
- Retrospective review of medical records for 499 neonates meeting 2013 ROP screening criteria.
- Analysis of weekly weights using logistic regression to establish a postnatal weight gain criterion.
- Development of the CO-ROP model by combining gestational age, birth weight, and the new weight gain criterion.
Main Results:
- The CO-ROP model identified infants with gestational age ≤30 weeks, birth weight ≤1500 g, and net weight gain ≤650 g by 1 month.
- CO-ROP demonstrated 100% sensitivity for high-grade ROP and 96.4% for all ROP grades.
- Implementing CO-ROP could reduce the number of infants screened by 23.7%, with a potential 45.9% reduction if calibrated for high-grade ROP detection only.
Conclusions:
- The CO-ROP model offers a simple yet effective approach to ROP screening.
- It maintains high sensitivity for ROP detection while significantly decreasing the number of infants requiring screening.
- Despite a small sample size, CO-ROP shows promise for improving ROP screening efficiency in clinical practice and future research.