Related Experiment Video
Updated: Mar 25, 2026

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Seed loss in prostate brachytherapy : Operator dependency and impact on dosimetry
Nancy El-Bared1, Natanel Sebbag1, Dominic Béliveau-Nadeau1
1Département de Radio-Oncologie, Centre hospitalier de l'Université de Montréal-Hôpital Notre-Dame, 1560 Sherbrooke St. E., H2L 4M1, Montreal, QC, Canada.
Introduction:
The aim of our study was to review seed loss and its impact on dosimetry as well as the influence of the treating physician on seed loss and dosimetry in patients treated with prostate brachytherapy using permanent loose (125)I implant.
Patients And Methods:
We analyzed 1087 consecutive patients treated by two physicians between July 2005 and April 2015 at a single institution. Pelvic fluoroscopic imaging was done 30 days post implant and a chest X-ray when seed loss was observed.
Results:
Seed loss occurred in 19.4 % of patients: in 20.0 % of implants done by the most experienced physician and in 17.2 % by the less experienced physician (p = 0.4) and migration to the thorax occurred in 5.9 % (6.9 vs. 2.2 %, p = 0.004). The mean seed loss rate was 0.57 % [standard deviation (SD) 1.39] and the mean rate of seeds in the thorax was 0.14 % (SD 0.65). The most experienced physician had a higher mean number of seeds lost: 0.36 versus 0.25 (p = 0.055), and a higher mean number of seed migration to the thorax: 0.1 versus 0.02 (p < 0.001). When at least one seed was lost, a decrease of 4.2 Gy (p < 0.001) in the D90 and a decrease of 3.5 % (p = 0.002) in the V150 was observed.
Conclusion:
We found a significant decrease in V150 and D90 with the occurrence of seed loss. Furthermore, we found a difference in seed migration among the physicians demonstrating that seed loss is operator dependant.